Plunger Operators
Show:

Item # 75026-27-21

Highlights:

Can be used as end of travel device or thumb valve. Lever travel is 3/8″ (10mm). Actuation force is 4.5 Lbs.

Operating pressure range 0-145 PSI. Actuation force@ 90 PSI. is approx. 13.5 Lbs.

Valve body dimensions are 1.968″ L .625″ W 1.25″ H. Through body mounting holes 3/16″ Dia.

Flat Lever extends 1.0625″ from valve body. Travel 0.562″.

Plunger diameter is 9/32″ and extends 55″ from valve body. Plunger travel 1875″ ?0.4″

For valve specifications see appendix. For detail dimensions contact factory.Can be used as end of travel device or thumb valve. Lever travel is 3/8″ (10mm). Actuation force is 4.5 Lbs.

Operating pressure range 0-145 PSI. Actuation force@ 90 PSI. is approx. 13.5 Lbs.

Valve body dimensions are 1.968″ L .625″ W 1.25″ H. Through body mounting holes 3/16″ Dia.

Flat Lever extends 1.0625″ from valve body. Travel 0.562″.

Plunger diameter is 9/32″ and extends 55″ from valve body. Plunger travel 1875″ ?0.4″

For valve specifications see appendix. For detail dimensions contact factory.

Item # 75027-60-10

Highlights:

Can be used as a door closed switch, material position detector or an end of travel detector. A double plunger is available which can be used on machine carriages to reverse direction of travel. Air pilot assist reduces actuation force to 1.8 lbs., minimum supply pressure 35 PSI.

Operating pressure range 35-145 PSI Actuation force at 90 PSI. is approx. 1.8 Lbs.

Approximate valve body dimensions for 1/8 ported valves are 3.5″ L (4 way body no. 2S) x 1.375″ H x 0.75″ W. For body no. 10P- 4.75″ L x 2″ H x 1″W. Approximate dimensions for 1/4 ported valves are 4.75″ L x 2″ H x 1″ W. Mounting hole 5/8″ diameter.

Plunger diameter 5/32″ and extends 0.625″ from valve body. Plunger travel is 0.125″.

For valve specifications see appendix. For detail dimensions contact factory.

Item # 75046-60-21

Highlights:

Can be used as a door closed switch, material position detector or an end of travel detector. A double plunger is available which can be used on machine carriages to reverse direction of travel. Air pilot assist reduces actuation force to 1.8 lbs., minimum supply pressure 35 PSI.

Operating pressure range 35-145 PSI Actuation force at 90 PSI. is approx. 1.8 Lbs.

Approximate valve body dimensions for 1/8 ported valves are 3.5″ L (4 way body no. 2S) x 1.375″ H x 0.75″ W. For body no. 10P- 4.75″ L x 2″ H x 1″W. Approximate dimensions for 1/4 ported valves are 4.75″ L x 2″ H x 1″ W. Mounting hole 5/8″ diameter.

Plunger diameter 5/32″ and extends 0.625″ from valve body. Plunger travel is 0.125″.

For valve specifications see appendix. For detail dimensions contact factory.

Item # 75046-60-31

Highlights:

Can be used as a door closed switch, material position detector or an end of travel detector. A double plunger is available which can be used on machine carriages to reverse direction of travel. Air pilot assist reduces actuation force to 1.8 lbs., minimum supply pressure 35 PSI.

Operating pressure range 35-145 PSI Actuation force at 90 PSI. is approx. 1.8 Lbs.

Approximate valve body dimensions for 1/8 ported valves are 3.5″ L (4 way body no. 2S) x 1.375″ H x 0.75″ W. For body no. 10P- 4.75″ L x 2″ H x 1″W. Approximate dimensions for 1/4 ported valves are 4.75″ L x 2″ H x 1″ W. Mounting hole 5/8″ diameter.

Plunger diameter 5/32″ and extends 0.625″ from valve body. Plunger travel is 0.125″.

For valve specifications see appendix. For detail dimensions contact factory.

Item # 75046-74-21

Highlights:

One way roller lever operates valve only in one direction. Actuation force is 14 ounces and roller lever travel is approx. 5/32 inch (4mm).

Operating pressure range 35-145 PSI. Minimum pressure 35 PSI. Actuation force at 90 PSI, is approx. 14 ounces.

Approximate valve body dimensions for 1/8 ported valves are 2.75″ L (3 way), 3.5″ L (4 way) x 1.375″ H x .75″ W. Approximate valve body dimensions for 1/4 ported valves are 4.75″ L x 2″ H x 1″ W. Roller arm extends 1.81″ beyond body and travel is .156 in actuate direction and .5″ in non actuate direction. Through body mounting holes 3/16″.

For valve specifications see appendix. For detail dimensions contact factory.

Item # 75047-60-10

Highlights:

Can be used as a door closed switch, material position detector or an end of travel detector. A double plunger is available which can be used on machine carriages to reverse direction of travel. Air pilot assist reduces actuation force to 1.8 lbs., minimum supply pressure 35 PSI.

Operating pressure range 35-145 PSI Actuation force at 90 PSI. is approx. 1.8 Lbs.

Approximate valve body dimensions for 1/8 ported valves are 3.5″ L (4 way body no. 2S) x 1.375″ H x 0.75″ W. For body no. 10P- 4.75″ L x 2″ H x 1″W. Approximate dimensions for 1/4 ported valves are 4.75″ L x 2″ H x 1″ W. Mounting hole 5/8″ diameter.

Plunger diameter 5/32″ and extends 0.625″ from valve body. Plunger travel is 0.125″.

For valve specifications see appendix. For detail dimensions contact factory.

Item # 75047-60-41

Highlights:

Knob valves have a small travel of about 1/4 inch and can be easily operated with the palm of a hand. Knobs are constructed of sturdy black molded material. Available in spring return, pneumatic return and push-pull versions.

Operating pressure range is 0-145 PSI. Actuation force at 90 PSI: 1/8 port approx. 3.4 Lbs., 1/4 port 11.3 Lbs.

For normally open function on 3 way valves reverse connect ports 1-3. For 2 way operation, plug port 3. Panel mounting hole size for 1/8-ported valves is 5/8 inch diameter, for 1/4-ported valves, 7/8 inch. Above panel dimensions: 1/8-ported are 1″ Dia. x 1.5? H: 1/4-ported -1.5″ Dia. x 2.25″ H.

Typical behind panel dimensions of 4 way 1/8 ported valves are 2.5″ D x 1.375″ W x 0.75″ H; 1/4 ported valves- 4″ D x 2″ W x 1″ H. For 3 way valves subtract 0.75″ from depth. For pneumatic return add 1″ to depth dimension. Allow space for fittings and tubing.

For valve specifications see appendix. For detail dimensions contact factory.

Item # 76022-21-21

Highlights:

Valves are similar to units above except have been modified with special seals and springs for use in vacuum applications.

Operating pressure range is 0 to 145 PSI. Pilot port size is 1/8. Actuation pressure (pilot pressure) is 35 PSI minimum.

Operating pressure range is 0 to 145 PSI. Pilot port size is 1/8. Actuation pressure (pilot pressure) is 35 PSI minimum.

Through body mounting holes are 3/16″ for 1/8 and 1/4 ported valves, 1/4″ for 1/2 ported valves.

For valve specifications see appendix. For detail dimensions contact factory.

Item # 76022-21-22

Highlights:

Used as position or end of travel detector. Valve configurations include pneumatic reset types which can be used in conjunction with pushbuttons or other control devices to manually or automatically reset valve. A double plunger is also available which can be used on machine carriages to reverse direction of travel. Operating force is 7.9 Lbs. and plunger travel is approx. 3/16 inch (5 mm).

Operating pressure range 0-145 PSI, Actuation force at 90 PSI, is approx. 7.9 Lbs.

For normally open function on 3 way valve reverse connect ports 1-3. For 2 way operation, plug port 3.

Typical valve body dimensions are 2.5″ L (3 way). 3.15″ L (4 way) x 1.375″ H x 0.75″ W. Add 1″ to L dim for pneumatic reset types. Through body mounting holes 3/16″ dia.

Plunger diameter is 0.25″ and extends .669″ from valve body. Plunger travel Is 1875″ ? 0.04″

For valve specifications see appendix. For detail dimensions contact factory.

Item # 76022-22-21

Highlights:

Depressing plunger operates valve. Used to detect material position or as an end of travel valve. Plunger travel approx. 3/16 inch (5mm). Actuating force is 7.9 Lbs.

Operating pressure range 0-145 PS1 Actuation force at 90 PSI. is approx. 7.9 Lbs.

For normally open function on 3 way valve, reverse connect ports 1-3. For 2 way operation, plug port 3.

Typical valve body dimensions are 2.5″ L (3 way), 3.15″ L (4 way) x 1.375″ H x .75″ W. Mounting hole 5/8″ diameter.

Through body mounting holes 3/16″ dia.

Plunger diameter is 0.25″ and extends 0.875″ from valve body. Plunger travel is 0.1875″ ? 0.04″

For valve specifications see appendix. For detail dimensions contact factory.

Item # 76022-32-21

Highlights:

Can be used as a door closed switch, material position detector or an end of travel detector. A double plunger is available which can be used on machine carriages to reverse direction of travel. Air pilot assist reduces actuation force to 1.8 lbs., minimum supply pressure 35 PSI.

Operating pressure range 35-145 PSI Actuation force at 90 PSI. is approx. 1.8 Lbs.

Approximate valve body dimensions for 1/8 ported valves are 3.5″ L (4 way body no. 2S) x 1.375″ H x 0.75″ W. For body no. 10P- 4.75″ L x 2″ H x 1″W. Approximate dimensions for 1/4 ported valves are 4.75″ L x 2″ H x 1″ W. Mounting hole 5/8″ diameter.

Plunger diameter 5/32″ and extends 0.625″ from valve body. Plunger travel is 0.125″.

For valve specifications see appendix. For detail dimensions contact factory.

Item # 76023-21-10

Highlights:

Used as position or end of travel detector. Valve configurations include pneumatic reset types which can be used in conjunction with pushbuttons or other control devices to manually or automatically reset valve. A double plunger is also available which can be used on machine carriages to reverse direction of travel. Operating force is 7.9 Lbs. and plunger travel is approx. 3/16 inch (5 mm).

Operating pressure range 0-145 PSI, Actuation force at 90 PSI, is approx. 7.9 Lbs.

For normally open function on 3 way valve reverse connect ports 1-3. For 2 way operation, plug port 3.

Typical valve body dimensions are 2.5″ L (3 way). 3.15″ L (4 way) x 1.375″ H x 0.75″ W. Add 1″ to L dim for pneumatic reset types. Through body mounting holes 3/16″ dia.

Plunger diameter is 0.25″ and extends .669″ from valve body. Plunger travel Is 1875″ ? 0.04″

For valve specifications see appendix. For detail dimensions contact factory.