Item # 75023-23-10
Used as a pneumatic limit switch or position detector. Roller arm travel is 3/8? (10mm). Actuating force is 4.5 Lbs. Options include valves with pneumatic reset used in conjunction with other controlling devices to reset valve. A double roller lever valve can be used on machine carriages to reverse direction of travel.
Operating pressure range is 0-145 PSI. Actuation force @ 90 PSI, is approx. 4.5 Lbs.
For normally open function on 3 way valve, reverse connect ports 1-3. For 2 way operation, plug port 3.
Typical valve body dimensions are 2.5? L (3 way), 3.15? L (4 way) x 1.375? H x .75? W. Add 1? to L dim. for pneumatic reset types. Through body mounting holes are 3/16? diameter.
Roller Lever extends 1.343? beyond body and travel is .39? +/- .04?.
For valve specifications see appendix. For detail dimensions contact factory.
Item # PT35FY1
The PT timer is an adjustable precise time delay pneumatic device. The timer is available with an on delay (NC), or an off delay (NO) output. The timer has 1/8 inch NPT ports.
The PT series timer combines a pneumatic timing mechanism with a floating spool valve assembly to provide a wide range of adjustable time control for fluid power systems. The timing assembly, which operates independently of the control pressure, is available in nine different ranges from one tenth of a second to 60 minutes, adjustable by means of a time-calibrated dial. Timing action is initiated by a motor diaphragm operated by a control pressure of from 5 to 140 PSIG.
The timer is equipped with a multi purpose 3 way output valve allowing it to be used as normally open, normally closed or as a diverter.
The PT is designed for panel or surface mounting. Panel mounted versions include a 3 13/16 inch square bezel while surface mounted units are equipped with a bracket for vertical mounting. If required, The PT can be specially calibrated for mounting horizontally.
On Delay Timer Operation Pilot pressure is applied to the control port to start timing. After the timer reaches its set time, the valve switches over. Removal of the pilot signal at any time resets the timer.
Item # PT35DY1
The PT timer is an adjustable precise time delay pneumatic device. The timer is available with an on delay (NC), or an off delay (NO) output. The timer has 1/8 inch NPT ports.
The PT series timer combines a pneumatic timing mechanism with a floating spool valve assembly to provide a wide range of adjustable time control for fluid power systems. The timing assembly, which operates independently of the control pressure, is available in nine different ranges from one tenth of a second to 60 minutes, adjustable by means of a time-calibrated dial. Timing action is initiated by a motor diaphragm operated by a control pressure of from 5 to 140 PSIG.
The timer is equipped with a multi purpose 3 way output valve allowing it to be used as normally open, normally closed or as a diverter.
The PT is designed for panel or surface mounting. Panel mounted versions include a 3 13/16 inch square bezel while surface mounted units are equipped with a bracket for vertical mounting. If required, The PT can be specially calibrated for mounting horizontally.
On Delay Timer Operation Pilot pressure is applied to the control port to start timing. After the timer reaches its set time, the valve switches over. Removal of the pilot signal at any time resets the timer.
Item # 51006-00
The Series 51 timer is an adjustable precise time delay control device. The timer is available with either an on delay- (NC) or off delay- (NO) 3 way built-in valve. It is designed for mounting along with valves or other logic devices and is available with 10-32 (M5) bottom ports, or 1/8″ NPT side ports. Bottom ported timers can also be panel mounted using (2) threaded M3 inserts on the top cover.
Timing operation can be set up in 2 ways; either via direct connection of the pressure line to be timed (1/8″ NPT ported only) or via a separate pilot signal. When pressure is applied to the input (or pilot port) the timing sequence begins by setting a vacuum within the timer. Using atmospheric pressure (independent of line pressure), the timer begins the preset timing cycle. At the end of the cycle an internal 3 way valve is switched providing an output. The timer resets automatically after removal of the control signal.
Item # PT35CY1
The PT timer is an adjustable precise time delay pneumatic device. The timer is available with an on delay (NC), or an off delay (NO) output. The timer has 1/8 inch NPT ports.
The PT series timer combines a pneumatic timing mechanism with a floating spool valve assembly to provide a wide range of adjustable time control for fluid power systems. The timing assembly, which operates independently of the control pressure, is available in nine different ranges from one tenth of a second to 60 minutes, adjustable by means of a time-calibrated dial. Timing action is initiated by a motor diaphragm operated by a control pressure of from 5 to 140 PSIG.
The timer is equipped with a multi purpose 3 way output valve allowing it to be used as normally open, normally closed or as a diverter.
The PT is designed for panel or surface mounting. Panel mounted versions include a 3 13/16 inch square bezel while surface mounted units are equipped with a bracket for vertical mounting. If required, The PT can be specially calibrated for mounting horizontally.
On Delay Timer Operation Pilot pressure is applied to the control port to start timing. After the timer reaches its set time, the valve switches over. Removal of the pilot signal at any time resets the timer.