Seal Kit Cyl. w/o Mag. 32mm (1)
Related Products
Recently Viewed
Item # 76084-15-00
ISO standard valves, solenoid operated, are available in 2 versions of 3 position valves; with all ports open or all ports closed in the center (off) position.
For technical details of valves, contact factory. See accessory section for manifolds and sub bases
Item # 76046-60-31
Can be used as a door closed switch, material position detector or an end of travel detector. A double plunger is available which can be used on machine carriages to reverse direction of travel. Air pilot assist reduces actuation force to 1.8 lbs., minimum supply pressure 35 PSI.
Operating pressure range 35-145 PSI Actuation force at 90 PSI. is approx. 1.8 Lbs.
Approximate valve body dimensions for 1/8 ported valves are 3.5″ L (4 way body no. 2S) x 1.375″ H x 0.75″ W. For body no. 10P- 4.75″ L x 2″ H x 1″W. Approximate dimensions for 1/4 ported valves are 4.75″ L x 2″ H x 1″ W. Mounting hole 5/8″ diameter.
Plunger diameter 5/32″ and extends 0.625″ from valve body. Plunger travel is 0.125″.
For valve specifications see appendix. For detail dimensions contact factory.
Item # 76022-61-24
Mushroom Heads provide easy palm operation of valve. Mushroom diameter is 1-3/8 inch. Button can be mounted in panels up to 1/2 inch thick or mounted via through body holes.
Operating pressure range is 0 to 145 PSI. Actuation force at 90 PSI. is approx. 7.9 Lbs.
For normally open function on 3 way valve reverse connect ports 1-3. For 2 way operation, plug port 3.
Panel mounting hole is 1 3/16 inch (30 mm) diameter. Above panel dimensions are 1.375″ Dia. x 0.875″ H. (Mushroom) or 0.375″ H. (Flush Head).
Behind panel dimensions of 3 way valve – 3.25″ D x 1.375″ H x 0.75″ W; 4 way valve- 4″ D x 1.375″ H x 75″ W. Allow space for fittings and tubing.
Valve through body mounting holes are 3/16″ diameter.
For valve specifications see appendix. For detail dimensions contact factory.
Item # 51006-00US
The Series 51 timer is an adjustable precise time delay control device. The timer is available with either an on delay- (NC) or off delay- (NO) 3 way built-in valve. It is designed for mounting along with valves or other logic devices and is available with 10-32 (M5) bottom ports, or 1/8″ NPT side ports. Bottom ported timers can also be panel mounted using (2) threaded M3 inserts on the top cover.
Timing operation can be set up in 2 ways; either via direct connection of the pressure line to be timed (1/8″ NPT ported only) or via a separate pilot signal. When pressure is applied to the input (or pilot port) the timing sequence begins by setting a vacuum within the timer. Using atmospheric pressure (independent of line pressure), the timer begins the preset timing cycle. At the end of the cycle an internal 3 way valve is switched providing an output. The timer resets automatically after removal of the control signal.
Item # PMT1D2B3
The Type PMT timer is an adjustable precise time delay control device. The timer is available with an on delay (NC) logic output.
Timing operation is dependent upon the input of a separate control signal which starts the timing sequence by setting a vacuum within the timer. Using atmospheric pressure (independent of line pressure), the timer begins the preset timing cycle. At the end of the cycle an internal 3 way valve is switched providing an output. The timer resets automatically after removal of the control signal.
The PMT has a separate subplate enabling the unit to be supplied with 10-32 or 1/8 NPT porting. The timer can be panel mounted with a bezel, or in the rear on a sub plate.
Item # PT35EY1
The PT timer is an adjustable precise time delay pneumatic device. The timer is available with an on delay (NC), or an off delay (NO) output. The timer has 1/8 inch NPT ports.
The PT series timer combines a pneumatic timing mechanism with a floating spool valve assembly to provide a wide range of adjustable time control for fluid power systems. The timing assembly, which operates independently of the control pressure, is available in nine different ranges from one tenth of a second to 60 minutes, adjustable by means of a time-calibrated dial. Timing action is initiated by a motor diaphragm operated by a control pressure of from 5 to 140 PSIG.
The timer is equipped with a multi purpose 3 way output valve allowing it to be used as normally open, normally closed or as a diverter.
The PT is designed for panel or surface mounting. Panel mounted versions include a 3 13/16 inch square bezel while surface mounted units are equipped with a bracket for vertical mounting. If required, The PT can be specially calibrated for mounting horizontally.
On Delay Timer Operation Pilot pressure is applied to the control port to start timing. After the timer reaches its set time, the valve switches over. Removal of the pilot signal at any time resets the timer.
Item # PT31A
The PT timer is an adjustable precise time delay pneumatic device. The timer is available with an on delay (NC), or an off delay (NO) output. The timer has 1/8 inch NPT ports.
The PT series timer combines a pneumatic timing mechanism with a floating spool valve assembly to provide a wide range of adjustable time control for fluid power systems. The timing assembly, which operates independently of the control pressure, is available in nine different ranges from one tenth of a second to 60 minutes, adjustable by means of a time-calibrated dial. Timing action is initiated by a motor diaphragm operated by a control pressure of from 5 to 140 PSIG.
The timer is equipped with a multi purpose 3 way output valve allowing it to be used as normally open, normally closed or as a diverter.
The PT is designed for panel or surface mounting. Panel mounted versions include a 3 13/16 inch square bezel while surface mounted units are equipped with a bracket for vertical mounting. If required, The PT can be specially calibrated for mounting horizontally.
On Delay Timer Operation Pilot pressure is applied to the control port to start timing. After the timer reaches its set time, the valve switches over. Removal of the pilot signal at any time resets the timer.