Weight | 0.37 lbs |
---|
Item # 19104-020
Price Summary
- $137.78
- $137.78
- $137.78
Com Cyl. W/Mag. D/A Fem Thrd
Related Products
Recently Viewed
Item # 76097-71-42
Valves are constructed to the European ISO standard, fit on ISO manifolds or sub-plates and are interchangeable amongst manufacturers. Standard pneumatically operated valves are listed.
Single air piloted ISO 1 and ISO 2 valves are available with manual resets (ISO pump valves). A pneumatic “not/not” valve is also available.
Contact factory for Details.
For technical details of ISO valves contact factory. See accessory section for manifolds and sub bases.
Item # 75024-05-00
Three position valves can be used to position cylinder piston rods or switch air supplies to alternate devices. Flat mounted spool valves are available in 2 versions; with all ports open or all ports closed in the center (off) position. Springs return the valve to the center position when the coil power is switched off.
Operating pressure range is 35 to 145 PSI.
Through body mounting holes are 3/16″.
For valve specifications see appendix. See valve accessory section for electrical connectors. For detail dimensions contact factory.
Item # 52010
Instant Push-In Fittings for 4mm (5/32″) O.D. Tubing
Instant push-in fittings provide a fast means of connecting pneumatic systems. Air connections are made by pushing tubing into fitting. Removal of tubing is done by pressing in on the brass collar, releasing tube. Series 52 fittings are designed for 5/32 inch (4mm) tubing and are constructed with a brass base and an anodized aluminum collar. Series 56 push-in fittings are constructed the same except have molded collars, and accept 1/8 inch (6mm) tubing.
Item # 76024-25-29
Three position valves are used mostly to position cylinders manually. The operator controls the cylinder direction by moving the lever side to side. Valves with all ports open in the center position allow the cylinder piston rod to move freely, while valves with all ports closed in the center position will hold the cylinder in the desired position when the lever is returned lo center. Valves can be panel or body mounted.
Operating pressure range Is 0-145 PSI. Actuation force at 90 PSI, is approx. 3.4 Lbs.
Panel mounting hole size for 1/8-ported valves is 5/8 inch diameter, for 1/4-ported valves, 7/8 inch. Through body mounting holes are 3/16″ dia.
Typical dimensions of spring return 1/8 ported valves are 4″ L x 1.375″ W x .75″ D. For 1/4 ported valves: 5.375″ L x 2″ W x 1″ D. Above panel dimensions including handle for 1/8-ported valves – 2.5″. 1/4-ported valves -3.375″. Allow space for fittings and tubing.
For valve specifications see appendix. For detail dimensions contact factory.
Item # LPM16-20
These pneumatic totalizers can be used as an event, part or lot counter. The counter registers pneumatic impulses on 4, 6 or 8 digit displays. Standard units operate with impulse pressures between 25 and 100 psi. Low pressure models operate between 7.5 and 30 psi. A variety of options include panel mounting with screws or mounting clips and surface mount with base or rear stud. The counters are available with or without manual reset.
Item # 76027-92-00
Solenoid operated, air piloted poppet valves are available in single, double, priority and external air pilot supply versions. Priority version overrides signal from opposite solenoid to assure return to valve home position. Valves with external air pilot connections are used when switching pressures below 35 PSI.
Poppet valves usually provide higher flow rates than other types of valves because of flow path design.
Valves include a red manual override for easy testing. Encapsulated coils provide splash proof protection when used with plug connectors. Valves can be mounted individually using through body holes or assembled on manifolds.
Operating pressure range is 35 to 145 PSI. (Use valves with external pilot for switching lower pressures).
Through body holes are 3/16″ for 1/8 and 1/4 ported valves, 1/4 ? for 1/2 ported valves.
For valve specifications see appendix. See accessory section for connectors and manifolds. For detail dimensions contact factory.
Item # 76123-91-00
Solenoid operated, air piloted spool valves are available in single, double, priority and external air pilot versions. Valve designs use a stainless steel spool moving within a sleeve to direct airflow to the ports of the valve. Spool valves are known for their long life capability.
Valves are available in 1/8 and 1/4 port sizes and have an operating range of 35 to 145 PSI.
Valves include a red manual override and encapsulated coils and can be individually mounted or assembled on manifolds.
Operating pressure range is 35 to 145 PSI. (Use valves with external pilot for switching lower pressures.)
Through body mounting holes are 3/16″.
For valve specifications see appendix. See accessory section for electrical connectors and manifolds. For detail dimensions contact factory.
Item # 76083-95-00
Valves are constructed to the European ISO standard permitting interchangeability between manufacturers. ISO valves have a standard mounting configuration. Valves are also available with a European automotive standard coil configuration (CNOMO).
For technical details of ISO valves contact factory. See accessory section for manifolds and sub bases.
Item # PT35CY1
The PT timer is an adjustable precise time delay pneumatic device. The timer is available with an on delay (NC), or an off delay (NO) output. The timer has 1/8 inch NPT ports.
The PT series timer combines a pneumatic timing mechanism with a floating spool valve assembly to provide a wide range of adjustable time control for fluid power systems. The timing assembly, which operates independently of the control pressure, is available in nine different ranges from one tenth of a second to 60 minutes, adjustable by means of a time-calibrated dial. Timing action is initiated by a motor diaphragm operated by a control pressure of from 5 to 140 PSIG.
The timer is equipped with a multi purpose 3 way output valve allowing it to be used as normally open, normally closed or as a diverter.
The PT is designed for panel or surface mounting. Panel mounted versions include a 3 13/16 inch square bezel while surface mounted units are equipped with a bracket for vertical mounting. If required, The PT can be specially calibrated for mounting horizontally.
On Delay Timer Operation Pilot pressure is applied to the control port to start timing. After the timer reaches its set time, the valve switches over. Removal of the pilot signal at any time resets the timer.