Weight | 0.25 lbs |
---|
Item # 2415-010
Price Summary
- $67.98
- $67.98
- $67.98
Min. Stainless Cyl. S/A Stud
Related Products
Recently Viewed
Item # 76087-95-00
Valves are constructed to the European ISO standard permitting interchangeability between manufacturers. ISO valves have a standard mounting configuration. Valves are also available with a European automotive standard coil configuration (CNOMO).
For technical details of ISO valves contact factory. See accessory section for manifolds and sub bases.
Item # 76420-02-04
Two sizes of manifold kits are available (1/8 and 1/4 ported) for standard directional control valves, pneumatically or electrically operated (4 way, In-Line type, 2 or 3 position, except valve types 76123, 76124, 76127). Manifolds are single piece aluminum bases with common supply and exhaust ports on each end (1/8 or 1/4 metric respectively). For NPT supply ports, order supply line adaptor kit separately. Manifold kits include all valve mounting hardware, which accommodates both NPT, or Metric ported versions of valves. A hollow bolt is used to connect the valve to the base and supply the line air pressure. Two brass sleeves, sealed with O-rings, connect the exhaust ports. If a valve station is unoccupied (for future use), a blanking bar kit must be used to block manifold ports. Manifolds can be fastened down by 4 threaded M5 holes. Two or more 1/8 ported manifolds can be linked together with the use of connecting nipples and threaded tie rods (up to 3/16″ dia.) using the through body holes on the sides of the manifold to increase the number of stations.
Item # 76026-69-21
Foot pedal valves can be used to operate devices which hold work pieces in place on bench workstations or perform punching or drilling operations on production pieces. Housing shields pedal preventing accidental operation. Enclosure is constructed of polycarbonate and available in high visibility yellow or blue colors.
Operating pressure range is 0 to 145 PSI. Actuation force at 90 PSI. is approx. 8 lbs.
Enclosure dimensions are 9″ L x 5 5/8″ W x 4 5/8″ H. Enclosure- polycarbonate, valve body die cast aluminum housing with Buna N seals.
Foot pedals with 2 mm orifice valves have an internal non-accessible exhaust port.
Item # AL19-WG
AL indicators provide a 2 color visual indication of the presence or absence of air pressure in a system. The indicators are available in a variety of color choices. The AL series are fixed 2 color units that change color when air pressure is applied.
Units are designed for oil tight panel mounting. The rounded lens configuration provides for a 180° view of position.
Item # 75044-02-00
Solenoid operated, air piloted poppet valves are available in single, double, priority and external air pilot supply versions. Priority version overrides signal from opposite solenoid to assure return to valve home position. Valves with external air pilot connections are used when switching pressures below 35 PSI. Poppet valves usually provide higher flow rates than other types of valves because of flow path design. Valves include a red manual override for easy testing. Encapsulated coils provide splash proof protection when used with plug connectors. Valves can be mounted individually using through body holes or assembled on manifolds.
Operating pressure range is 35 to 145 PSI. (Use valves with external pilot for switching lower pressures).
Through body mounting holes are 3/16″ for 1/8 and 1/4 ported valves, 1/4″ for 1/2 ported valves.
For valve specifications see appendix. See accessory section for electrical connectors. For detail dimensions contact factory.
Itme # 51018-01
The Series 51 timer is an adjustable precise time delay control device. The timer is available with either an on delay- (NC) or off delay- (NO) 3 way built-in valve. It is designed for mounting along with valves or other logic devices and is available with 10-32 (M5) bottom ports, or 1/8″ NPT side ports. Bottom ported timers can also be panel mounted using (2) threaded M3 inserts on the top cover.
Timing operation can be set up in 2 ways; either via direct connection of the pressure line to be timed (1/8″ NPT ported only) or via a separate pilot signal. When pressure is applied to the input (or pilot port) the timing sequence begins by setting a vacuum within the timer. Using atmospheric pressure (independent of line pressure), the timer begins the preset timing cycle. At the end of the cycle an internal 3 way valve is switched providing an output. The timer resets automatically after removal of the control signal.
Item # 75046-68-29
Foot pedals are available in 3 or 4 way spring return or maintained versions. Latching pedals can be used to lock work pieces in place, while spring return units can be used to perform work operations like punching, pressing etc.
Operating pressure range is 0 to 145 PSI. Actuation force at 90 PSI. is approx. 8 lbs.
Enclosure dimensions are 9″ L x 5 5/8″ W x 4 5/8″ H. Enclosure- polycarbonate, valve body die cast aluminum housing with Buna N seals.
Item # PT35F
The PT timer is an adjustable precise time delay pneumatic device. The timer is available with an on delay (NC), or an off delay (NO) output. The timer has 1/8 inch NPT ports.
The PT series timer combines a pneumatic timing mechanism with a floating spool valve assembly to provide a wide range of adjustable time control for fluid power systems. The timing assembly, which operates independently of the control pressure, is available in nine different ranges from one tenth of a second to 60 minutes, adjustable by means of a time-calibrated dial. Timing action is initiated by a motor diaphragm operated by a control pressure of from 5 to 140 PSIG.
The timer is equipped with a multi purpose 3 way output valve allowing it to be used as normally open, normally closed or as a diverter.
The PT is designed for panel or surface mounting. Panel mounted versions include a 3 13/16 inch square bezel while surface mounted units are equipped with a bracket for vertical mounting. If required, The PT can be specially calibrated for mounting horizontally.
On Delay Timer Operation Pilot pressure is applied to the control port to start timing. After the timer reaches its set time, the valve switches over. Removal of the pilot signal at any time resets the timer.