Min. Stainless Cyl. S/A Stud
Related Products
Recently Viewed
Item # 76024-71-58
Spool Design, In Line Mounting
Three position spool valves are used mostly to position cylinders. Valves with all ports open in the center position allow the cylinder piston rod to move freely, while valves with all ports closed in the center position will hold the cylinder in the desired position when no pilot pressure is present. A third type keeps line pressure on both sides of the cylinder piston.
Pneumatically actuated spool valves are available in 1/8 and 1/4 port sizes and require a minimum of 35 PSI operating pressure. Valves can be mounted with through body holes or assembled on manifolds.
Pilot port size (for actuation): 1/8 for all size valves.
Operating pressure range 35 to 145 PSI. Actuation force (pilot pressure): 35 PSI minimum.
Mounting via 4 through body holes 3/16? Dia.
For valve specifications see appendix. See accessory section for manifolds if required. For detail dimensions contact factory.
Item # 47086
For direct mounting on cylinder or valve ports, with L-banjo type instant push-in fitting and captive adjusting screw.
Item # 75067-94-00
Solenoid operated, air piloted poppet valves are available in single, double, priority and external air pilot supply versions. Priority version overrides signal from opposite solenoid to assure return to valve home position. Valves with external air pilot connections are used when switching pressures below 35 PSI. Poppet valves usually provide higher flow rates than other types of valves because of flow path design. Valves include a red manual override for easy testing. Encapsulated coils provide splash proof protection when used with plug connectors. Valves can be mounted individually using through body holes or assembled on manifolds.
Operating pressure range is 35 to 145 PSI. (Use valves with external pilot for switching lower pressures).
Through body mounting holes are 3/16″ for 1/8 and 1/4 ported valves, 1/4″ for 1/2 ported valves.
For valve specifications see appendix. See accessory section for electrical connectors. For detail dimensions contact factory.
Item # 76022-25-00
Lever valves can be used to manually switch air supplies on equipment or operate cylinders and other devices. Valves can be panel mounted or fastened to a surface via body mounting holes. Handles have a contemporary black molded grip and require 3.4 lbs. of force to operate. Valves are available in spring return, pneumatic return and maintained position versions.
Operating pressure range is 0-145 PSI. Actuation force at 90 PSI, is approx. 3.4 Lbs.
For normally open function on 3 way valves, reverse connect ports 1-3. For 2 way operation, plug port 3.
Panel mounting hole size for 1/8-ported valves is 5/8 inch diameter, for 1/4 ported valves, 7/8 inch. Through body mounting holes are 3/16″ dia.
Typical dimensions of 4 way 1/8 ported valves are 3.75″ L x 1.375″ W x 0.75″ D. For 1/4 ported valves: 4.75″ L x 2″ W x 1″ D. For 3 way valves subtract 0.75″ from L dimension. For pneumatic return valves add 1″ to L dimension. Allow space for fittings and tubing.
For valve specifications see appendix. For detail dimensions contact factory.
Itme # 51018-01
The Series 51 timer is an adjustable precise time delay control device. The timer is available with either an on delay- (NC) or off delay- (NO) 3 way built-in valve. It is designed for mounting along with valves or other logic devices and is available with 10-32 (M5) bottom ports, or 1/8″ NPT side ports. Bottom ported timers can also be panel mounted using (2) threaded M3 inserts on the top cover.
Timing operation can be set up in 2 ways; either via direct connection of the pressure line to be timed (1/8″ NPT ported only) or via a separate pilot signal. When pressure is applied to the input (or pilot port) the timing sequence begins by setting a vacuum within the timer. Using atmospheric pressure (independent of line pressure), the timer begins the preset timing cycle. At the end of the cycle an internal 3 way valve is switched providing an output. The timer resets automatically after removal of the control signal.
Item # 76067-81-42
Pneumatically operated poppet valves are available in single, double or with priority port actuators. The priority port design overrides the signal from the opposite pilot operator to insure return to home position. Poppet valves rely on O rings and gaskets to seal passage ways within the valve and generally offer higher flow rates than other types of valves.
These valves are available in port sizes of 1/8, 1/4 and 1/2. Pilot ports are 1/8 for all size valves and require minimum of 35 PSI operating pressure. Single air pilot valves have an air supported spring return and require a pilot pressure equal to or greater than the air supply pressure at port 1. Valves can be mounted using through body holes or assembled on manifolds.
Pilot port size (for actuation): 1/8 for all size valves.
Operating pressure range 35 to 145 PSI. Actuation force (pilot pressure): 35 PSI minimum.
Mounting via 4 through body holes 3/16? Dia. (1/2? ported valves- 1/4? Dia.).
For valve specifications see appendix. See accessory section for manifolds if required. For detail dimensions contact factory.
Item # 75044-25-39
Three position valves are used mostly to position cylinders manually. The operator controls the cylinder direction by moving the lever side to side. Valves with all ports open in the center position allow the cylinder piston rod to move freely, while valves with all ports closed in the center position will hold the cylinder in the desired position when the lever is returned lo center. Valves can be panel or body mounted.
Operating pressure range Is 0-145 PSI. Actuation force at 90 PSI, is approx. 3.4 Lbs.
Panel mounting hole size for 1/8-ported valves is 5/8 inch diameter, for 1/4-ported valves, 7/8 inch. Through body mounting holes are 3/16″ dia.
Typical dimensions of spring return 1/8 ported valves are 4″ L x 1.375″ W x .75″ D. For 1/4 ported valves: 5.375″ L x 2″ W x 1″ D. Above panel dimensions including handle for 1/8-ported valves – 2.5″. 1/4-ported valves -3.375″. Allow space for fittings and tubing.
For valve specifications see appendix. For detail dimensions contact factory.
Item # 75347-91-00
Solenoid operated, air piloted poppet valves are available in single, double, priority and external air pilot supply versions. Priority version overrides signal from opposite solenoid to assure return to valve home position. Valves with external air pilot connections are used when switching pressures below 35 PSI.
Poppet valves usually provide higher flow rates than other types of valves because of flow path design.
Valves include a red manual override for easy testing. Encapsulated coils provide splash proof protection when used with plug connectors. Valves can be mounted individually using through body holes or assembled on manifolds.
Operating pressure range is 35 to 145 PSI. (Use valves with external pilot for switching lower pressures).
Through body holes are 3/16″ for 1/8 and 1/4 ported valves, 1/4 ? for 1/2 ported valves.
For valve specifications see appendix. See accessory section for connectors and manifolds. For detail dimensions contact factory.