Three position valves are used mostly to position cylinders manually. The operator controls the cylinder direction by moving the lever side to side. Valves with all ports open in the center position allow the cylinder piston rod to move freely, while valves with all ports closed in the center position will hold the cylinder in the desired position when the lever is returned lo center. Valves can be panel or body mounted.
Operating pressure range Is 0-145 PSI. Actuation force at 90 PSI, is approx. 3.4 Lbs.
Panel mounting hole size for 1/8-ported valves is 5/8 inch diameter, for 1/4-ported valves, 7/8 inch. Through body mounting holes are 3/16″ dia.
Typical dimensions of spring return 1/8 ported valves are 4″ L x 1.375″ W x .75″ D. For 1/4 ported valves: 5.375″ L x 2″ W x 1″ D. Above panel dimensions including handle for 1/8-ported valves – 2.5″. 1/4-ported valves -3.375″. Allow space for fittings and tubing.
For valve specifications see appendix. For detail dimensions contact factory.
Item # AL19-BKA
AL indicators provide a 2 color visual indication of the presence or absence of air pressure in a system. The indicators are available in a variety of color choices. The AL series are fixed 2 color units that change color when air pressure is applied.
Units are designed for oil tight panel mounting. The rounded lens configuration provides for a 180° view of position.
Item # PT31DY1
The PT timer is an adjustable precise time delay pneumatic device. The timer is available with an on delay (NC), or an off delay (NO) output. The timer has 1/8 inch NPT ports.
The PT series timer combines a pneumatic timing mechanism with a floating spool valve assembly to provide a wide range of adjustable time control for fluid power systems. The timing assembly, which operates independently of the control pressure, is available in nine different ranges from one tenth of a second to 60 minutes, adjustable by means of a time-calibrated dial. Timing action is initiated by a motor diaphragm operated by a control pressure of from 5 to 140 PSIG.
The timer is equipped with a multi purpose 3 way output valve allowing it to be used as normally open, normally closed or as a diverter.
The PT is designed for panel or surface mounting. Panel mounted versions include a 3 13/16 inch square bezel while surface mounted units are equipped with a bracket for vertical mounting. If required, The PT can be specially calibrated for mounting horizontally.
On Delay Timer Operation Pilot pressure is applied to the control port to start timing. After the timer reaches its set time, the valve switches over. Removal of the pilot signal at any time resets the timer.
Item # 51012-01
The Series 51 timer is an adjustable precise time delay control device. The timer is available with either an on delay- (NC) or off delay- (NO) 3 way built-in valve. It is designed for mounting along with valves or other logic devices and is available with 10-32 (M5) bottom ports, or 1/8″ NPT side ports. Bottom ported timers can also be panel mounted using (2) threaded M3 inserts on the top cover.
Timing operation can be set up in 2 ways; either via direct connection of the pressure line to be timed (1/8″ NPT ported only) or via a separate pilot signal. When pressure is applied to the input (or pilot port) the timing sequence begins by setting a vacuum within the timer. Using atmospheric pressure (independent of line pressure), the timer begins the preset timing cycle. At the end of the cycle an internal 3 way valve is switched providing an output. The timer resets automatically after removal of the control signal.
Item # 75023-71-42
Spool valves rely on a stainless steel spool moving within a sleeve to direct flow to the ports of the valve. Spool designs are known for their long life capability. Available in single, double or with priority port actuators. The priority port design overrides the signal from the opposite pilot operator to insure return to home position. Pneumatically actuated spool valves are available in 1/8 and 1/4 port sizes and require a minimum of 35 PSI operating pressure. Valves can be mounted individually using through body holes or assembled on manifolds.
Pilot port size (for actuation): 1/8 for all size valves.
Operating pressure range 35 to 145 PSI. Actuation force (pilot pressure): 35 PSI minimum.
Mounting via 4 through body holes 3/16″ Dia.
For valve specifications see appendix. See accessory section for manifolds if required. For detail dimensions contact factory.
Item # 48255-60US
The Series 48 miniature regulator has characteristics similar to the Series 50 miniature regulator. The unit, however, is specially designed for systems where constant adjustment of pressure is not necessary.
The Series 48 regulator is designed for mounting in panel interiors. Two (10-32) tapped holes are provided in the side of the housing for attachment to panel or mounting brackets. Ports (2) are 180? apart on the sides of the unit housing.
A variety of regulation ranges is available to suit most applications. Special designs are available.
Item # PT45AY1
The PT timer is an adjustable precise time delay pneumatic device. The timer is available with an on delay (NC), or an off delay (NO) output. The timer has 1/8 inch NPT ports.
The PT series timer combines a pneumatic timing mechanism with a floating spool valve assembly to provide a wide range of adjustable time control for fluid power systems. The timing assembly, which operates independently of the control pressure, is available in nine different ranges from one tenth of a second to 60 minutes, adjustable by means of a time-calibrated dial. Timing action is initiated by a motor diaphragm operated by a control pressure of from 5 to 140 PSIG.
The timer is equipped with a multi purpose 3 way output valve allowing it to be used as normally open, normally closed or as a diverter.
The PT is designed for panel or surface mounting. Panel mounted versions include a 3 13/16 inch square bezel while surface mounted units are equipped with a bracket for vertical mounting. If required, The PT can be specially calibrated for mounting horizontally.
Off Delay Timer Operation Applying pilot pressure of at least 100ms in duration to the control port shifts the valve. When the pilot pressure is removed, the timing sequence begins. After the timer reaches its set time, the valve switches off. Re-applying the pilot pressure resets the timer and valve.