Description | Standard Clip Mfg. |
Digit | 4 |
Mount Type | Panel Mounted |
Operating Pressure Range | 7.5 to 30 psi |
Connections | 10-32 (M5) port, Option 1/8 |
Display | Black with white digits |
Reset | With Manual Reset |
Media | Filtered Air |
Duty Cycle | Continuous Min. pulse duration 8 ms Min. pause 10 ms |
Operating Ambient | 0 to +60 ºC 32 to 140 ºF |
Weight | 2.5 oz. to 4.5 oz. |
Materials | Molded Body Steel Frame |
Height | 7/8 in. |
Width | 1 1/2 in. |
Depth | 2 5/8 in. |
Panel Cut Out | 7/8 in. H x 1 5/16 in. W |
Options | Reset Guard Spade Key Reset Secret Reset |
Item # LPM14-21
Price Summary
- $289.07
- $289.07
- $289.07
These pneumatic totalizers can be used as an event, part or lot counter. The counter registers pneumatic impulses on 4, 6 or 8 digit displays. Standard units operate with impulse pressures between 25 and 100 psi. Low pressure models operate between 7.5 and 30 psi. A variety of options include panel mounting with screws or mounting clips and surface mount with base or rear stud. The counters are available with or without manual reset.
Weight | 0.25 lbs |
---|
Be the first to review “Item # LPM14-21” Cancel reply
You must be logged in to post a review.
Related Products
Item # PM16-20
These pneumatic totalizers can be used as an event, part or lot counter. The counter registers pneumatic impulses on 4, 6 or 8 digit displays. Standard units operate with impulse pressures between 25 and 100 psi. Low pressure models operate between 7.5 and 30 psi. A variety of options include panel mounting with screws or mounting clips and surface mount with base or rear stud. The counters are available with or without manual reset.
Item # PM14-20
These pneumatic totalizers can be used as an event, part or lot counter. The counter registers pneumatic impulses on 4, 6 or 8 digit displays. Standard units operate with impulse pressures between 25 and 100 psi. Low pressure models operate between 7.5 and 30 psi. A variety of options include panel mounting with screws or mounting clips and surface mount with base or rear stud. The counters are available with or without manual reset.
Item # LPM16-00
These pneumatic totalizers can be used as an event, part or lot counter. The counter registers pneumatic impulses on 4, 6 or 8 digit displays. Standard units operate with impulse pressures between 25 and 100 psi. Low pressure models operate between 7.5 and 30 psi. A variety of options include panel mounting with screws or mounting clips and surface mount with base or rear stud. The counters are available with or without manual reset.
Item # LPM16-21
These pneumatic totalizers can be used as an event, part or lot counter. The counter registers pneumatic impulses on 4, 6 or 8 digit displays. Standard units operate with impulse pressures between 25 and 100 psi. Low pressure models operate between 7.5 and 30 psi. A variety of options include panel mounting with screws or mounting clips and surface mount with base or rear stud. The counters are available with or without manual reset.
Item # LPM14-20
These pneumatic totalizers can be used as an event, part or lot counter. The counter registers pneumatic impulses on 4, 6 or 8 digit displays. Standard units operate with impulse pressures between 25 and 100 psi. Low pressure models operate between 7.5 and 30 psi. A variety of options include panel mounting with screws or mounting clips and surface mount with base or rear stud. The counters are available with or without manual reset.
Item # LAPM14-00
These pneumatic totalizers can be used as an event, part or lot counter. The counter registers pneumatic impulses on 4, 6 or 8 digit displays. Standard units operate with impulse pressures between 25 and 100 psi. Low pressure models operate between 7.5 and 30 psi. A variety of options include panel mounting with screws or mounting clips and surface mount with base or rear stud. The counters are available with or without manual reset.
Item # PM14-00
These pneumatic totalizers can be used as an event, part or lot counter. The counter registers pneumatic impulses on 4, 6 or 8 digit displays. Standard units operate with impulse pressures between 25 and 100 psi. Low pressure models operate between 7.5 and 30 psi. A variety of options include panel mounting with screws or mounting clips and surface mount with base or rear stud. The counters are available with or without manual reset.
Item # LPM16-01
These pneumatic totalizers can be used as an event, part or lot counter. The counter registers pneumatic impulses on 4, 6 or 8 digit displays. Standard units operate with impulse pressures between 25 and 100 psi. Low pressure models operate between 7.5 and 30 psi. A variety of options include panel mounting with screws or mounting clips and surface mount with base or rear stud. The counters are available with or without manual reset.
Item # PM14-11
These pneumatic totalizers can be used as an event, part or lot counter. The counter registers pneumatic impulses on 4, 6 or 8 digit displays. Standard units operate with impulse pressures between 25 and 100 psi. Low pressure models operate between 7.5 and 30 psi. A variety of options include panel mounting with screws or mounting clips and surface mount with base or rear stud. The counters are available with or without manual reset.
Item # LPM16-20
These pneumatic totalizers can be used as an event, part or lot counter. The counter registers pneumatic impulses on 4, 6 or 8 digit displays. Standard units operate with impulse pressures between 25 and 100 psi. Low pressure models operate between 7.5 and 30 psi. A variety of options include panel mounting with screws or mounting clips and surface mount with base or rear stud. The counters are available with or without manual reset.
Item # LPM14-10
These pneumatic totalizers can be used as an event, part or lot counter. The counter registers pneumatic impulses on 4, 6 or 8 digit displays. Standard units operate with impulse pressures between 25 and 100 psi. Low pressure models operate between 7.5 and 30 psi. A variety of options include panel mounting with screws or mounting clips and surface mount with base or rear stud. The counters are available with or without manual reset.
Item # LPM16-11
These pneumatic totalizers can be used as an event, part or lot counter. The counter registers pneumatic impulses on 4, 6 or 8 digit displays. Standard units operate with impulse pressures between 25 and 100 psi. Low pressure models operate between 7.5 and 30 psi. A variety of options include panel mounting with screws or mounting clips and surface mount with base or rear stud. The counters are available with or without manual reset.
Recently Viewed
Item # 48200-00-50-10
The Series 48 miniature regulator has characteristics similar to the Series 50 miniature regulator. The unit, however, is specially designed for systems where constant adjustment of pressure is not necessary.
The Series 48 regulator is designed for mounting in panel interiors. Two (10-32) tapped holes are provided in the side of the housing for attachment to panel or mounting brackets. Ports (2) are 180? apart on the sides of the unit housing.
A variety of regulation ranges is available to suit most applications. Special designs are available.
Item # PM14-10
These pneumatic totalizers can be used as an event, part or lot counter. The counter registers pneumatic impulses on 4, 6 or 8 digit displays. Standard units operate with impulse pressures between 25 and 100 psi. Low pressure models operate between 7.5 and 30 psi. A variety of options include panel mounting with screws or mounting clips and surface mount with base or rear stud. The counters are available with or without manual reset.
Item # 75046-01-00
Three way poppet design valves are solenoid operated, air pilot assisted. Valves include a red manual override lever for easy testing of pneumatic circuits. Coils are encapsulated for long life. Available in standard versions, or with a port for external air supply used for switching pressures below 35 PSI.
Operating pressure range is 35 to 145 PSI. (Use valves with external pilot for switching lower pressures).
For 2-way operation plug exhaust port 3. Through body mounting holes are 3/16″ for 1/8 and 1/4 ported valves, 1/4″ for 1/2 ported valves.
For valve specifications see appendix. See accessory section for electrical connectors. For detail dimensions contact factory.
Item # 76027-71-41
Pneumatically operated poppet valves are available in single, double or with priority port actuators. The priority port design overrides the signal from the opposite pilot operator to insure return to home position. Poppet valves rely on O rings and gaskets to seal passage ways within the valve and generally offer higher flow rates than other types of valves.
These valves are available in port sizes of 1/8, 1/4 and 1/2. Pilot ports are 1/8 for all size valves and require minimum of 35 PSI operating pressure. Single air pilot valves have an air supported spring return and require a pilot pressure equal to or greater than the air supply pressure at port 1. Valves can be mounted using through body holes or assembled on manifolds.
Pilot port size (for actuation): 1/8 for all size valves.
Operating pressure range 35 to 145 PSI. Actuation force (pilot pressure): 35 PSI minimum.
Mounting via 4 through body holes 3/16? Dia. (1/2? ported valves- 1/4? Dia.).
For valve specifications see appendix. See accessory section for manifolds if required. For detail dimensions contact factory.
Item # 50121
Brass metric sized fittings provide a full family of connectors for most applications in miniature pneumatics. Machined from solid brass stock, fittings are dependable, easy to install and reduce space requirements.
Series 50 fittings also include quick connect couplings and brass manifolds.
Item # LAPM14-01
These pneumatic totalizers can be used as an event, part or lot counter. The counter registers pneumatic impulses on 4, 6 or 8 digit displays. Standard units operate with impulse pressures between 25 and 100 psi. Low pressure models operate between 7.5 and 30 psi. A variety of options include panel mounting with screws or mounting clips and surface mount with base or rear stud. The counters are available with or without manual reset.
Item # 76420-02-09
Two sizes of manifold kits are available (1/8 and 1/4 ported) for standard directional control valves, pneumatically or electrically operated (4 way, In-Line type, 2 or 3 position, except valve types 76123, 76124, 76127). Manifolds are single piece aluminum bases with common supply and exhaust ports on each end (1/8 or 1/4 metric respectively). For NPT supply ports, order supply line adaptor kit separately. Manifold kits include all valve mounting hardware, which accommodates both NPT, or Metric ported versions of valves. A hollow bolt is used to connect the valve to the base and supply the line air pressure. Two brass sleeves, sealed with O-rings, connect the exhaust ports. If a valve station is unoccupied (for future use), a blanking bar kit must be used to block manifold ports. Manifolds can be fastened down by 4 threaded M5 holes. Two or more 1/8 ported manifolds can be linked together with the use of connecting nipples and threaded tie rods (up to 3/16″ dia.) using the through body holes on the sides of the manifold to increase the number of stations.
Item # AL15-AG
AL indicators provide a 2 color visual indication of the presence or absence of air pressure in a system. The indicators are available in a variety of color choices. The AL series are fixed 2 color units that change color when air pressure is applied.
Units are designed for oil tight panel mounting. The rounded lens configuration provides for a 180° view of position.
Item # 76127-91-00
Solenoid operated, air piloted poppet valves are available in single, double, priority and external air pilot supply versions. Priority version overrides signal from opposite solenoid to assure return to valve home position. Valves with external air pilot connections are used when switching pressures below 35 PSI.
Poppet valves usually provide higher flow rates than other types of valves because of flow path design.
Valves include a red manual override for easy testing. Encapsulated coils provide splash proof protection when used with plug connectors. Valves can be mounted individually using through body holes or assembled on manifolds.
Operating pressure range is 35 to 145 PSI. (Use valves with external pilot for switching lower pressures).
Through body holes are 3/16″ for 1/8 and 1/4 ported valves, 1/4 ? for 1/2 ported valves.
For valve specifications see appendix. See accessory section for connectors and manifolds. For detail dimensions contact factory.
There are no reviews yet.