Item # 76022-66-21
Shroud Head prevents accidental operation. Button is (lush with shroud surface and the diameter is 1 1/8 inches. Operating force 14 ounces.
Operating pressure range is 35 to 145 PSI. Minimum operating pressure is 35 PSI. Actuation force at 90 PSI. is approx 14 ozs.
Panel mounting hole is 7/8 inch (22 mm) diameter. Above panel dimensions are 1.375″ Dia. x 1″ H. (Mushroom) or 0.625″ H. (Shroud Head).
Behind panel dimensions of 3 way valve – 3.75″ D x 1.375″ H x 0.75″ W; 4 way valve – 4.25″ D x 1.375″ H x 0.75″ W.
Allow space for fittings and tubing.
Valve through body mounting holes are 3/16″ diameter.
For valve specifications see appendix. For detail dimensions contact factory.
Item # 76022-66-23
Shroud Head prevents accidental operation. Button is (lush with shroud surface and the diameter is 1 1/8 inches. Operating force 14 ounces.
Operating pressure range is 35 to 145 PSI. Minimum operating pressure is 35 PSI. Actuation force at 90 PSI. is approx 14 ozs.
Panel mounting hole is 7/8 inch (22 mm) diameter. Above panel dimensions are 1.375″ Dia. x 1″ H. (Mushroom) or 0.625″ H. (Shroud Head).
Behind panel dimensions of 3 way valve – 3.75″ D x 1.375″ H x 0.75″ W; 4 way valve – 4.25″ D x 1.375″ H x 0.75″ W.
Allow space for fittings and tubing.
Valve through body mounting holes are 3/16″ diameter.
For valve specifications see appendix. For detail dimensions contact factory.
Item # 76022-66-24
Operating pressure range is 35 to 145 PSI. Minimum operating pressure is 35 PSI. Actuation force at 90 PSI. is approx 14 ozs.
Panel mounting hole is 7/8 inch (22 mm) diameter. Above panel dimensions are 1.375″ Dia. x 1″ H. (Mushroom) or 0.625″ H. (Shroud Head).
Behind panel dimensions of 3 way valve – 3.75″ D x 1.375″ H x 0.75″ W; 4 way valve – 4.25″ D x 1.375″ H x 0.75″ W.
Allow space for fittings and tubing.
Valve through body mounting holes are 3/16″ diameter.
For valve specifications see appendix. For detail dimensions contact factory.
Item # 76022-71-21
Direct acting pneumatic operated spool valves are available with single, double or with priority actuators. Priority ports override signals from opposite pilot operator to ensure positive return to home position. Minimum pilot pressure 35 PSI.
Operating pressure range is 0 to 145 PSI. Pilot port size is 1/8.
Compact valves actuation force (pilot pressure): 50 PSI minimum. Dimensions: 2 7/8″ L x 5/8″ W x 1 1/4″ D.
Spool design valves actuation force – 35 PSI minimum. Dimensions: approx. 3 1/4″ L x 1 3/8″ W x 7/8″ D, (Double pilot 3 5/8″ L).
Mounting via through body holes 3/16″ dia.
For valve specifications see appendix. For detail dimensions contact factory.
Item # 76022-71-22
Direct acting pneumatic operated spool valves are available with single, double or with priority actuators. Priority ports override signals from opposite pilot operator to ensure positive return to home position. Minimum pilot pressure 35 PSI.
Operating pressure range is 0 to 145 PSI. Pilot port size is 1/8.
Compact valves actuation force (pilot pressure): 50 PSI minimum. Dimensions: 2 7/8″ L x 5/8″ W x 1 1/4″ D.
Spool design valves actuation force – 35 PSI minimum. Dimensions: approx. 3 1/4″ L x 1 3/8″ W x 7/8″ D, (Double pilot 3 5/8″ L).
Mounting via through body holes 3/16″ dia.
For valve specifications see appendix. For detail dimensions contact factory.
Item # 76022-71-47
Direct acting pneumatic operated spool valves are available with single, double or with priority actuators. Priority ports override signals from opposite pilot operator to ensure positive return to home position. Minimum pilot pressure 35 PSI.
Operating pressure range is 0 to 145 PSI. Pilot port size is 1/8.
Compact valves actuation force (pilot pressure): 50 PSI minimum. Dimensions: 2 7/8″ L x 5/8″ W x 1 1/4″ D.
Spool design valves actuation force – 35 PSI minimum. Dimensions: approx. 3 1/4″ L x 1 3/8″ W x 7/8″ D, (Double pilot 3 5/8″ L).
Mounting via through body holes 3/16″ dia.
For valve specifications see appendix. For detail dimensions contact factory.
Item # 76023-21-10
Used as position or end of travel detector. Valve configurations include pneumatic reset types which can be used in conjunction with pushbuttons or other control devices to manually or automatically reset valve. A double plunger is also available which can be used on machine carriages to reverse direction of travel. Operating force is 7.9 Lbs. and plunger travel is approx. 3/16 inch (5 mm).
Operating pressure range 0-145 PSI, Actuation force at 90 PSI, is approx. 7.9 Lbs.
For normally open function on 3 way valve reverse connect ports 1-3. For 2 way operation, plug port 3.
Typical valve body dimensions are 2.5″ L (3 way). 3.15″ L (4 way) x 1.375″ H x 0.75″ W. Add 1″ to L dim for pneumatic reset types. Through body mounting holes 3/16″ dia.
Plunger diameter is 0.25″ and extends .669″ from valve body. Plunger travel Is 1875″ ? 0.04″
For valve specifications see appendix. For detail dimensions contact factory.
Item # 76023-21-41
Used as position or end of travel detector. Valve configurations include pneumatic reset types which can be used in conjunction with pushbuttons or other control devices to manually or automatically reset valve. A double plunger is also available which can be used on machine carriages to reverse direction of travel. Operating force is 7.9 Lbs. and plunger travel is approx. 3/16 inch (5 mm).
Operating pressure range 0-145 PSI, Actuation force at 90 PSI, is approx. 7.9 Lbs.
For normally open function on 3 way valve reverse connect ports 1-3. For 2 way operation, plug port 3.
Typical valve body dimensions are 2.5″ L (3 way). 3.15″ L (4 way) x 1.375″ H x 0.75″ W. Add 1″ to L dim for pneumatic reset types. Through body mounting holes 3/16″ dia.
Plunger diameter is 0.25″ and extends .669″ from valve body. Plunger travel Is 1875″ ? 0.04″
For valve specifications see appendix. For detail dimensions contact factory.
Item # 76023-21-42
Used as position or end of travel detector. Valve configurations include pneumatic reset types which can be used in conjunction with pushbuttons or other control devices to manually or automatically reset valve. A double plunger is also available which can be used on machine carriages to reverse direction of travel. Operating force is 7.9 Lbs. and plunger travel is approx. 3/16 inch (5 mm).
Operating pressure range 0-145 PSI, Actuation force at 90 PSI, is approx. 7.9 Lbs.
For normally open function on 3 way valve reverse connect ports 1-3. For 2 way operation, plug port 3.
Typical valve body dimensions are 2.5″ L (3 way). 3.15″ L (4 way) x 1.375″ H x 0.75″ W. Add 1″ to L dim for pneumatic reset types. Through body mounting holes 3/16″ dia.
Plunger diameter is 0.25″ and extends .669″ from valve body. Plunger travel Is 1875″ ? 0.04″
For valve specifications see appendix. For detail dimensions contact factory.
Item # 76023-22-41
Depressing plunger operates valve. Used to detect material position or as an end of travel valve. Plunger travel approx. 3/16 inch (5mm). Actuating force is 7.9 Lbs.
Operating pressure range 0-145 PS1 Actuation force at 90 PSI. is approx. 7.9 Lbs.
For normally open function on 3 way valve, reverse connect ports 1-3. For 2 way operation, plug port 3.
Typical valve body dimensions are 2.5″ L (3 way), 3.15″ L (4 way) x 1.375″ H x .75″ W. Mounting hole 5/8″ diameter.
Through body mounting holes 3/16″ dia.
Plunger diameter is 0.25″ and extends 0.875″ from valve body. Plunger travel is 0.1875″ ? 0.04″
For valve specifications see appendix. For detail dimensions contact factory.
Item # 76023-23-10
Used as a pneumatic limit switch or position detector. Roller arm travel is 3/8? (10mm). Actuating force is 4.5 Lbs. Options include valves with pneumatic reset used in conjunction with other controlling devices to reset valve. A double roller lever valve can be used on machine carriages to reverse direction of travel.
Operating pressure range is 0-145 PSI. Actuation force @ 90 PSI, is approx. 4.5 Lbs.
For normally open function on 3 way valve, reverse connect ports 1-3. For 2 way operation, plug port 3.
Typical valve body dimensions are 2.5? L (3 way), 3.15? L (4 way) x 1.375? H x .75? W. Add 1? to L dim. for pneumatic reset types. Through body mounting holes are 3/16? diameter.
Roller Lever extends 1.343? beyond body and travel is .39? +/- .04?.
For valve specifications see appendix. For detail dimensions contact factory.
Item # 76023-23-41
Used as a pneumatic limit switch or position detector. Roller arm travel is 3/8? (10mm). Actuating force is 4.5 Lbs. Options include valves with pneumatic reset used in conjunction with other controlling devices to reset valve. A double roller lever valve can be used on machine carriages to reverse direction of travel.
Operating pressure range is 0-145 PSI. Actuation force @ 90 PSI, is approx. 4.5 Lbs.
For normally open function on 3 way valve, reverse connect ports 1-3. For 2 way operation, plug port 3.
Typical valve body dimensions are 2.5? L (3 way), 3.15? L (4 way) x 1.375? H x .75? W. Add 1? to L dim. for pneumatic reset types. Through body mounting holes are 3/16? diameter.
Roller Lever extends 1.343? beyond body and travel is .39? +/- .04?.
For valve specifications see appendix. For detail dimensions contact factory.