Weight | 0.37 lbs |
---|
Item # 19005-015
Price Summary
- $120.62
- $120.62
- $120.62
Comp. Cyl. W/Mag. S/A Fem Thrd
Related Products
Recently Viewed
Item # 76023-58-41
Key provides security for locking off air supply to equipment
Operating pressure range std. type- 0-145 PSI: air piloted types minimum 35 PSI. Actuation force: std. – 7.9 lbs., air pilot assisted types 1.8 lbs.
Above panel dim. are 1.125″ dia. x 0.5″ H (key) or 2 75″ H (wobble). Behind panel dimensions are 4″ (3 way), 4.5″ (4 way) D. x 1.375″ H x 75 W.
For valve specifications see appendix. For detail dimensions contact factory.
Item # 75024-02-00
Three position valves can be used to position cylinder piston rods or switch air supplies to alternate devices. In line spool valves are available in 2 versions; with all ports open or all ports closed in the center (off) position. Springs return the valve to the center position when the coil power is switched off. Valves can be individually mounted using through body holes or assembled on manifolds.
Operating pressure range is 35 to 145 PSI. (Use valves with external pilot for switching lower pressures).
Through body mounting holes are 3/16″.
For valve specifications see appendix. See accessory section for connectors and manifolds. For detail dimensions contact factory.
Item # 75023-47-41
Selector switch maintains valve position.
Operating pressure range std. type- 0-145 PSI: air piloted types minimum 35 PSI. Actuation force: std – 7.9 lbs., air pilot assisted types 7.8 lbs.
Above panel dimensions are 1.125″ dia. x 1″ H. Behind panel dimensions are 4″ (3 way), 4.5″ (4 way) D. x 1.375″ H. x .75 W.
For valve specifications see appendix. For detail dimensions contact factory.
Item # PM18-00
These pneumatic totalizers can be used as an event, part or lot counter. The counter registers pneumatic impulses on 4, 6 or 8 digit displays. Standard units operate with impulse pressures between 25 and 100 psi. Low pressure models operate between 7.5 and 30 psi. A variety of options include panel mounting with screws or mounting clips and surface mount with base or rear stud. The counters are available with or without manual reset.
Item # 76023-62-44
Flush Head pushbuttons are used to prevent accidental operation or provide flat panel appearance. Button is flush with shroud surface and diameter is 1-3/8 inch.
Operating pressure range is 0 to 145 PSI. Actuation force at 90 PSI. is approx. 7.9 Lbs.
For normally open function on 3 way valve reverse connect ports 1-3. For 2 way operation, plug port 3.
Panel mounting hole is 1 3/16 inch (30 mm) diameter. Above panel dimensions are 1.375″ Dia. x 0.875″ H. (Mushroom) or 0.375″ H. (Flush Head).
Behind panel dimensions of 3 way valve – 3.25″ D x 1.375″ H x 0.75″ W; 4 way valve- 4″ D x 1.375″ H x 75″ W. Allow space for fittings and tubing.
Valve through body mounting holes are 3/16″ diameter.
For valve specifications see appendix. For detail dimensions contact factory.
Item # PT41F
The PT timer is an adjustable precise time delay pneumatic device. The timer is available with an on delay (NC), or an off delay (NO) output. The timer has 1/8 inch NPT ports.
The PT series timer combines a pneumatic timing mechanism with a floating spool valve assembly to provide a wide range of adjustable time control for fluid power systems. The timing assembly, which operates independently of the control pressure, is available in nine different ranges from one tenth of a second to 60 minutes, adjustable by means of a time-calibrated dial. Timing action is initiated by a motor diaphragm operated by a control pressure of from 5 to 140 PSIG.
The timer is equipped with a multi purpose 3 way output valve allowing it to be used as normally open, normally closed or as a diverter.
The PT is designed for panel or surface mounting. Panel mounted versions include a 3 13/16 inch square bezel while surface mounted units are equipped with a bracket for vertical mounting. If required, The PT can be specially calibrated for mounting horizontally.
Off Delay Timer Operation Applying pilot pressure of at least 100ms in duration to the control port shifts the valve. When the pilot pressure is removed, the timing sequence begins. After the timer reaches its set time, the valve switches off. Re-applying the pilot pressure resets the timer and valve.