Weight | 0.25 lbs |
---|
Item # 38250-012
Price Summary
- $127.82
- $127.82
- $127.82
Min. Brass Cylinder.D/A,Stud
Related Products
Recently Viewed
Item # 50051
Brass metric sized fittings provide a full family of connectors for most applications in miniature pneumatics. Machined from solid brass stock, fittings are dependable, easy to install and reduce space requirements.
Series 50 fittings also include quick connect couplings and brass manifolds.
Item # PT45D
The PT timer is an adjustable precise time delay pneumatic device. The timer is available with an on delay (NC), or an off delay (NO) output. The timer has 1/8 inch NPT ports.
The PT series timer combines a pneumatic timing mechanism with a floating spool valve assembly to provide a wide range of adjustable time control for fluid power systems. The timing assembly, which operates independently of the control pressure, is available in nine different ranges from one tenth of a second to 60 minutes, adjustable by means of a time-calibrated dial. Timing action is initiated by a motor diaphragm operated by a control pressure of from 5 to 140 PSIG.
The timer is equipped with a multi purpose 3 way output valve allowing it to be used as normally open, normally closed or as a diverter.
The PT is designed for panel or surface mounting. Panel mounted versions include a 3 13/16 inch square bezel while surface mounted units are equipped with a bracket for vertical mounting. If required, The PT can be specially calibrated for mounting horizontally.
Off Delay Timer Operation Applying pilot pressure of at least 100ms in duration to the control port shifts the valve. When the pilot pressure is removed, the timing sequence begins. After the timer reaches its set time, the valve switches off. Re-applying the pilot pressure resets the timer and valve.
Item # 75023-65-44
Mushroom Heads provide easy operation of valve. An internal air pilot assist using the supply air. reduces the force necessary to operate valve to 14 ounces.
Operating pressure range is 35 to 145 PSI. Minimum operating pressure is 35 PSI. Actuation force at 90 PSI. is approx 14 ozs.
Panel mounting hole is 7/8 inch (22 mm) diameter. Above panel dimensions are 1.375″ Dia. x 1″ H. (Mushroom) or 0.625″ H. (Shroud Head).
Behind panel dimensions of 3 way valve – 3.75″ D x 1.375″ H x 0.75″ W; 4 way valve – 4.25″ D x 1.375″ H x 0.75″ W.
Allow space for fittings and tubing.
Valve through body mounting holes are 3/16″ diameter.
For valve specifications see appendix. For detail dimensions contact factory.
Item # PMT1G1B3
The Type PMT timer is an adjustable precise time delay control device. The timer is available with an on delay (NC) logic output.
Timing operation is dependent upon the input of a separate control signal which starts the timing sequence by setting a vacuum within the timer. Using atmospheric pressure (independent of line pressure), the timer begins the preset timing cycle. At the end of the cycle an internal 3 way valve is switched providing an output. The timer resets automatically after removal of the control signal.
The PMT has a separate subplate enabling the unit to be supplied with 10-32 or 1/8 NPT porting. The timer can be panel mounted with a bezel, or in the rear on a sub plate.
Item # 76026-21-31
Depressing plunger operates valve, used to detect material position or as an end of travel valve. Plunger travel approx. 3/16 inch (5mm). Actuation force is 13.5 Lbs.
Operating pressure range 0-145 PSI. Actuation force@ 90 PSI. is approx. 13.5 Lbs.
Valve body dimensions are 1.968″ L .625″ W 1.25″ H. Through body mounting holes 3/16″ Dia.
Flat Lever extends 1.0625″ from valve body. Travel 0.562″.
Plunger diameter is 9/32″ and extends 55″ from valve body. Plunger travel 1875″ ?0.4″
For valve specifications see appendix. For detail dimensions contact factory.
Item # 76067-81-42
Pneumatically operated poppet valves are available in single, double or with priority port actuators. The priority port design overrides the signal from the opposite pilot operator to insure return to home position. Poppet valves rely on O rings and gaskets to seal passage ways within the valve and generally offer higher flow rates than other types of valves.
These valves are available in port sizes of 1/8, 1/4 and 1/2. Pilot ports are 1/8 for all size valves and require minimum of 35 PSI operating pressure. Single air pilot valves have an air supported spring return and require a pilot pressure equal to or greater than the air supply pressure at port 1. Valves can be mounted using through body holes or assembled on manifolds.
Pilot port size (for actuation): 1/8 for all size valves.
Operating pressure range 35 to 145 PSI. Actuation force (pilot pressure): 35 PSI minimum.
Mounting via 4 through body holes 3/16? Dia. (1/2? ported valves- 1/4? Dia.).
For valve specifications see appendix. See accessory section for manifolds if required. For detail dimensions contact factory.
Item # PT45CY1
The PT timer is an adjustable precise time delay pneumatic device. The timer is available with an on delay (NC), or an off delay (NO) output. The timer has 1/8 inch NPT ports.
The PT series timer combines a pneumatic timing mechanism with a floating spool valve assembly to provide a wide range of adjustable time control for fluid power systems. The timing assembly, which operates independently of the control pressure, is available in nine different ranges from one tenth of a second to 60 minutes, adjustable by means of a time-calibrated dial. Timing action is initiated by a motor diaphragm operated by a control pressure of from 5 to 140 PSIG.
The timer is equipped with a multi purpose 3 way output valve allowing it to be used as normally open, normally closed or as a diverter.
The PT is designed for panel or surface mounting. Panel mounted versions include a 3 13/16 inch square bezel while surface mounted units are equipped with a bracket for vertical mounting. If required, The PT can be specially calibrated for mounting horizontally.
Off Delay Timer Operation Applying pilot pressure of at least 100ms in duration to the control port shifts the valve. When the pilot pressure is removed, the timing sequence begins. After the timer reaches its set time, the valve switches off. Re-applying the pilot pressure resets the timer and valve.