Vlv 5 wy cntr A & B press
Item # 770123200
Price Summary
- $155.71
- $155.71
- $155.71
Weight | 0.19 lbs |
---|
Be the first to review “Item # 770123200” Cancel reply
You must be logged in to post a review.
Related Products
Recently Viewed
Item # LAPM14-01
These pneumatic totalizers can be used as an event, part or lot counter. The counter registers pneumatic impulses on 4, 6 or 8 digit displays. Standard units operate with impulse pressures between 25 and 100 psi. Low pressure models operate between 7.5 and 30 psi. A variety of options include panel mounting with screws or mounting clips and surface mount with base or rear stud. The counters are available with or without manual reset.
Item # 48255-50US
The Series 48 miniature regulator has characteristics similar to the Series 50 miniature regulator. The unit, however, is specially designed for systems where constant adjustment of pressure is not necessary.
The Series 48 regulator is designed for mounting in panel interiors. Two (10-32) tapped holes are provided in the side of the housing for attachment to panel or mounting brackets. Ports (2) are 180? apart on the sides of the unit housing.
A variety of regulation ranges is available to suit most applications. Special designs are available.
Item # 51012-01US
The Series 51 timer is an adjustable precise time delay control device. The timer is available with either an on delay- (NC) or off delay- (NO) 3 way built-in valve. It is designed for mounting along with valves or other logic devices and is available with 10-32 (M5) bottom ports, or 1/8″ NPT side ports. Bottom ported timers can also be panel mounted using (2) threaded M3 inserts on the top cover.
Timing operation can be set up in 2 ways; either via direct connection of the pressure line to be timed (1/8″ NPT ported only) or via a separate pilot signal. When pressure is applied to the input (or pilot port) the timing sequence begins by setting a vacuum within the timer. Using atmospheric pressure (independent of line pressure), the timer begins the preset timing cycle. At the end of the cycle an internal 3 way valve is switched providing an output. The timer resets automatically after removal of the control signal.
Item # 51018-00US
The Series 51 timer is an adjustable precise time delay control device. The timer is available with either an on delay- (NC) or off delay- (NO) 3 way built-in valve. It is designed for mounting along with valves or other logic devices and is available with 10-32 (M5) bottom ports, or 1/8″ NPT side ports. Bottom ported timers can also be panel mounted using (2) threaded M3 inserts on the top cover.
Timing operation can be set up in 2 ways; either via direct connection of the pressure line to be timed (1/8″ NPT ported only) or via a separate pilot signal. When pressure is applied to the input (or pilot port) the timing sequence begins by setting a vacuum within the timer. Using atmospheric pressure (independent of line pressure), the timer begins the preset timing cycle. At the end of the cycle an internal 3 way valve is switched providing an output. The timer resets automatically after removal of the control signal.
Item # 48255-60US
The Series 48 miniature regulator has characteristics similar to the Series 50 miniature regulator. The unit, however, is specially designed for systems where constant adjustment of pressure is not necessary.
The Series 48 regulator is designed for mounting in panel interiors. Two (10-32) tapped holes are provided in the side of the housing for attachment to panel or mounting brackets. Ports (2) are 180? apart on the sides of the unit housing.
A variety of regulation ranges is available to suit most applications. Special designs are available.
Item # 51006-00US
The Series 51 timer is an adjustable precise time delay control device. The timer is available with either an on delay- (NC) or off delay- (NO) 3 way built-in valve. It is designed for mounting along with valves or other logic devices and is available with 10-32 (M5) bottom ports, or 1/8″ NPT side ports. Bottom ported timers can also be panel mounted using (2) threaded M3 inserts on the top cover.
Timing operation can be set up in 2 ways; either via direct connection of the pressure line to be timed (1/8″ NPT ported only) or via a separate pilot signal. When pressure is applied to the input (or pilot port) the timing sequence begins by setting a vacuum within the timer. Using atmospheric pressure (independent of line pressure), the timer begins the preset timing cycle. At the end of the cycle an internal 3 way valve is switched providing an output. The timer resets automatically after removal of the control signal.
Item # 51018-01US
The Series 51 timer is an adjustable precise time delay control device. The timer is available with either an on delay- (NC) or off delay- (NO) 3 way built-in valve. It is designed for mounting along with valves or other logic devices and is available with 10-32 (M5) bottom ports, or 1/8″ NPT side ports. Bottom ported timers can also be panel mounted using (2) threaded M3 inserts on the top cover.
Timing operation can be set up in 2 ways; either via direct connection of the pressure line to be timed (1/8″ NPT ported only) or via a separate pilot signal. When pressure is applied to the input (or pilot port) the timing sequence begins by setting a vacuum within the timer. Using atmospheric pressure (independent of line pressure), the timer begins the preset timing cycle. At the end of the cycle an internal 3 way valve is switched providing an output. The timer resets automatically after removal of the control signal.
Item # 51012-00US
The Series 51 timer is an adjustable precise time delay control device. The timer is available with either an on delay- (NC) or off delay- (NO) 3 way built-in valve. It is designed for mounting along with valves or other logic devices and is available with 10-32 (M5) bottom ports, or 1/8″ NPT side ports. Bottom ported timers can also be panel mounted using (2) threaded M3 inserts on the top cover.
Timing operation can be set up in 2 ways; either via direct connection of the pressure line to be timed (1/8″ NPT ported only) or via a separate pilot signal. When pressure is applied to the input (or pilot port) the timing sequence begins by setting a vacuum within the timer. Using atmospheric pressure (independent of line pressure), the timer begins the preset timing cycle. At the end of the cycle an internal 3 way valve is switched providing an output. The timer resets automatically after removal of the control signal.
tem # 76047-81-41
Pneumatically operated poppet valves are available in single, double or with priority port actuators. The priority port design overrides the signal from the opposite pilot operator to insure return to home position. Poppet valves rely on O rings and gaskets to seal passage ways within the valve and generally offer higher flow rates than other types of valves.
These valves are available in port sizes of 1/8, 1/4 and 1/2. Pilot ports are 1/8 for all size valves and require minimum of 35 PSI operating pressure. Single air pilot valves have an air supported spring return and require a pilot pressure equal to or greater than the air supply pressure at port 1. Valves can be mounted using through body holes or assembled on manifolds.
Pilot port size (for actuation): 1/8 for all size valves.
Operating pressure range 35 to 145 PSI. Actuation force (pilot pressure): 35 PSI minimum.
Mounting via 4 through body holes 3/16? Dia. (1/2? ported valves- 1/4? Dia.).
For valve specifications see appendix. See accessory section for manifolds if required. For detail dimensions contact factory.
Item # 75023-23-10
Used as a pneumatic limit switch or position detector. Roller arm travel is 3/8? (10mm). Actuating force is 4.5 Lbs. Options include valves with pneumatic reset used in conjunction with other controlling devices to reset valve. A double roller lever valve can be used on machine carriages to reverse direction of travel.
Operating pressure range is 0-145 PSI. Actuation force @ 90 PSI, is approx. 4.5 Lbs.
For normally open function on 3 way valve, reverse connect ports 1-3. For 2 way operation, plug port 3.
Typical valve body dimensions are 2.5? L (3 way), 3.15? L (4 way) x 1.375? H x .75? W. Add 1? to L dim. for pneumatic reset types. Through body mounting holes are 3/16? diameter.
Roller Lever extends 1.343? beyond body and travel is .39? +/- .04?.
For valve specifications see appendix. For detail dimensions contact factory.
Item # 75023-65-43
Mushroom Heads provide easy operation of valve. An internal air pilot assist using the supply air. reduces the force necessary to operate valve to 14 ounces.
Operating pressure range is 35 to 145 PSI. Minimum operating pressure is 35 PSI. Actuation force at 90 PSI. is approx 14 ozs.
Panel mounting hole is 7/8 inch (22 mm) diameter. Above panel dimensions are 1.375″ Dia. x 1″ H. (Mushroom) or 0.625″ H. (Shroud Head).
Behind panel dimensions of 3 way valve – 3.75″ D x 1.375″ H x 0.75″ W; 4 way valve – 4.25″ D x 1.375″ H x 0.75″ W.
Allow space for fittings and tubing.
Valve through body mounting holes are 3/16″ diameter.
For valve specifications see appendix. For detail dimensions contact factory.
Item # 75022-44-21
Push to latch, turn to unlatch. Can be used as an emergency stop button.
Operating pressure range std. type- 0-145 PSI, air piloted types minimum 35 PSI. Actuation force: std – 7.9 lbs , air pilot. assisted types 1 8 lbs.
Above panel dim are 1.125″ dia x 1.25″H. Behind panel dimensions are 4″ (3 way), 4.5″ (4 way) D. x 1.375″ H x 0.75 W.
For valve specifications see appendix. For detail dimensions contact factory.
Item # 75367-95-00
Solenoid operated, air piloted poppet valves are available in single, double, priority and external air pilot supply versions. Priority version overrides signal from opposite solenoid to assure return to valve home position. Valves with external air pilot connections are used when switching pressures below 35 PSI. Poppet valves usually provide higher flow rates than other types of valves because of flow path design. Valves include a red manual override for easy testing. Encapsulated coils provide splash proof protection when used with plug connectors. Valves can be mounted individually using through body holes or assembled on manifolds.
Operating pressure range is 35 to 145 PSI. (Use valves with external pilot for switching lower pressures).
Through body mounting holes are 3/16″ for 1/8 and 1/4 ported valves, 1/4″ for 1/2 ported valves.
For valve specifications see appendix. See accessory section for electrical connectors. For detail dimensions contact factory.
Item # 76420-00-46
Standard coils fit all general purpose solenoid valves, except ISO valves with CNOMO air pilots. Coils are encapsulated to keep out water, oil and other contaminants providing splash proof protection when used with sockets below. The 3-prong plug includes a ground connection for the coil frame. Terminals can also be connected using crimp-on wire terminals with a 1/4″ spade dimension. Coil power consumption: AC (60Hz) is 3.5VA, DC is 2.5 W.
There are no reviews yet.