Weight | 1.25 lbs |
---|
Item # A1250210DOM
Price Summary
- $371.98
- $371.98
- $371.98
CNOMOCYL
Be the first to review “Item # A1250210DOM” Cancel reply
You must be logged in to post a review.
Related Products
Recently Viewed
Item # 75023-48-41
Key provides security for locking off air supply to equipment
Operating pressure range std. type- 0-145 PSI: air piloted types minimum 35 PSI. Actuation force: std. – 7.9 lbs., air pilot assisted types 1.8 lbs.
Above panel dim. are 1.125″ dia. x 0.5″ H (key) or 2 75″ H (wobble). Behind panel dimensions are 4″ (3 way), 4.5″ (4 way) D. x 1.375″ H x 75 W.
For valve specifications see appendix. For detail dimensions contact factory.
Item # 76022-52-21
Shrouded Head helps prevent accidental operation of button.
Operating pressure range std. type- 0-145 PSI; air piloted types minimum 35 PSI. Actuation force: std. – 7.9 lbs., air pilot assisted types 1.8 Ibs.
Above panel dim. are 1.125″ dia. x .5″ H (shroud) or 1.25″ H (mushroom). Behind panel dim. are 4″ (3 way). 4.5″ (4 way) D. x 1.375″ H x .75 W.
For valve specifications see appendix. For detail dimensions contact factory.
Item # 76023-45-41
Wobble button can be operated by pushing mushroom head down or to the side.
Operating pressure range std. type- 0-145 PSI, air piloted types minimum 35 PSI. Actuation force: std – 7.9 lbs , air pilot. assisted types 1 8 lbs.
Above panel dim are 1.125″ dia x 1.25″H. Behind panel dimensions are 4″ (3 way), 4.5″ (4 way) D. x 1.375″ H x 0.75 W.
For valve specifications see appendix. For detail dimensions contact factory.
Item # 75023-51-41
Standard raised red pushbutton for momentary actuation
Operating pressure range std type – 0-145 PSI. air piloted types minimum 35 PSI. Actuation force: std. – 7.9 lbs., air pilot assisted types 18 lbs. Above panel dimensions 1.125″ dia. x 0.75″ H. Typical behind panel dimensions ate 4.75″ (3 way). 5.5″ (4 way) D. x 1.375″ H x 0.75′ W.
For valve specifications see appendix. For detail dimensions contact factory.
Item # 76022-61-23
Mushroom Heads provide easy palm operation of valve. Mushroom diameter is 1-3/8 inch. Button can be mounted in panels up to 1/2 inch thick or mounted via through body holes.
Operating pressure range is 0 to 145 PSI. Actuation force at 90 PSI. is approx. 7.9 Lbs.
For normally open function on 3 way valve reverse connect ports 1-3. For 2 way operation, plug port 3.
Panel mounting hole is 1 3/16 inch (30 mm) diameter. Above panel dimensions are 1.375″ Dia. x 0.875″ H. (Mushroom) or 0.375″ H. (Flush Head).
Behind panel dimensions of 3 way valve – 3.25″ D x 1.375″ H x 0.75″ W; 4 way valve- 4″ D x 1.375″ H x 75″ W. Allow space for fittings and tubing.
Valve through body mounting holes are 3/16″ diameter.
For valve specifications see appendix. For detail dimensions contact factory.
Item # 76420-02-06
Two sizes of manifold kits are available (1/8 and 1/4 ported) for standard directional control valves, pneumatically or electrically operated (4 way, In-Line type, 2 or 3 position, except valve types 76123, 76124, 76127). Manifolds are single piece aluminum bases with common supply and exhaust ports on each end (1/8 or 1/4 metric respectively). For NPT supply ports, order supply line adaptor kit separately. Manifold kits include all valve mounting hardware, which accommodates both NPT, or Metric ported versions of valves. A hollow bolt is used to connect the valve to the base and supply the line air pressure. Two brass sleeves, sealed with O-rings, connect the exhaust ports. If a valve station is unoccupied (for future use), a blanking bar kit must be used to block manifold ports. Manifolds can be fastened down by 4 threaded M5 holes. Two or more 1/8 ported manifolds can be linked together with the use of connecting nipples and threaded tie rods (up to 3/16″ dia.) using the through body holes on the sides of the manifold to increase the number of stations.
Item # 75046-69-29
Foot pedals are available in 3 or 4 way spring return or maintained versions. Latching pedals can be used to lock work pieces in place, while spring return units can be used to perform work operations like punching, pressing etc.
Operating pressure range is 0 to 145 PSI. Actuation force at 90 PSI. is approx. 8 lbs.
Enclosure dimensions are 9″ L x 5 5/8″ W x 4 5/8″ H. Enclosure- polycarbonate, valve body die cast aluminum housing with Buna N seals.
Item # 76023-21-10
Used as position or end of travel detector. Valve configurations include pneumatic reset types which can be used in conjunction with pushbuttons or other control devices to manually or automatically reset valve. A double plunger is also available which can be used on machine carriages to reverse direction of travel. Operating force is 7.9 Lbs. and plunger travel is approx. 3/16 inch (5 mm).
Operating pressure range 0-145 PSI, Actuation force at 90 PSI, is approx. 7.9 Lbs.
For normally open function on 3 way valve reverse connect ports 1-3. For 2 way operation, plug port 3.
Typical valve body dimensions are 2.5″ L (3 way). 3.15″ L (4 way) x 1.375″ H x 0.75″ W. Add 1″ to L dim for pneumatic reset types. Through body mounting holes 3/16″ dia.
Plunger diameter is 0.25″ and extends .669″ from valve body. Plunger travel Is 1875″ ? 0.04″
For valve specifications see appendix. For detail dimensions contact factory.
Item # 75022-43-21
Shrouded Head helps prevent accidental operation of button.
Operating pressure range std. type- 0-145 PSI; air piloted types minimum 35 PSI. Actuation force: std. – 7.9 lbs., air pilot assisted types 1.8 Ibs.
Above panel dim. are 1.125″ dia. x .5″ H (shroud) or 1.25″ H (mushroom). Behind panel dim. are 4″ (3 way). 4.5″ (4 way) D. x 1.375″ H x .75 W.
For valve specifications see appendix. For detail dimensions contact factory.
Item # 75022-54-21
Push to latch, turn to unlatch. Can be used as an emergency stop button.
Operating pressure range std. type- 0-145 PSI, air piloted types minimum 35 PSI. Actuation force: std – 7.9 lbs , air pilot. assisted types 1 8 lbs.
Above panel dim are 1.125″ dia x 1.25″H. Behind panel dimensions are 4″ (3 way), 4.5″ (4 way) D. x 1.375″ H x 0.75 W.
For valve specifications see appendix. For detail dimensions contact factory.
Item # 75367-95-00
Solenoid operated, air piloted poppet valves are available in single, double, priority and external air pilot supply versions. Priority version overrides signal from opposite solenoid to assure return to valve home position. Valves with external air pilot connections are used when switching pressures below 35 PSI. Poppet valves usually provide higher flow rates than other types of valves because of flow path design. Valves include a red manual override for easy testing. Encapsulated coils provide splash proof protection when used with plug connectors. Valves can be mounted individually using through body holes or assembled on manifolds.
Operating pressure range is 35 to 145 PSI. (Use valves with external pilot for switching lower pressures).
Through body mounting holes are 3/16″ for 1/8 and 1/4 ported valves, 1/4″ for 1/2 ported valves.
For valve specifications see appendix. See accessory section for electrical connectors. For detail dimensions contact factory.
Item # 76023-54-41
Shrouded Head helps prevent accidental operation of button.
Operating pressure range std. type- 0-145 PSI; air piloted types minimum 35 PSI. Actuation force: std. – 7.9 lbs., air pilot assisted types 1.8 Ibs.
Above panel dim. are 1.125″ dia. x .5″ H (shroud) or 1.25″ H (mushroom). Behind panel dim. are 4″ (3 way). 4.5″ (4 way) D. x 1.375″ H x .75 W.
For valve specifications see appendix. For detail dimensions contact factory.
Item # 75027-71-47
Pneumatically operated poppet valves are available in single, double or with priority port actuators. The priority port design overrides the signal from the opposite pilot operator to insure return to home position. Poppet valves rely on O rings and gaskets to seal passage ways within the valve and generally offer higher flow rates than other types of valves.
These valves are available in port sizes of 1/8, 1/4 and 1/2. Pilot ports are 1/8 for all size valves and require minimum of 35 PSI operating pressure. Single air pilot valves have an air supported spring return and require a pilot pressure equal to or greater than the air supply pressure at port 1. Valves can be mounted using through body holes or assembled on manifolds.
Pilot port size (for actuation): 1/8 for all size valves.
Operating pressure range 35 to 145 PSI. Actuation force (pilot pressure): 35 PSI minimum.
Mounting via 4 through body holes 3/16? Dia. (1/2? ported valves- 1/4? Dia.).
For valve specifications see appendix. See accessory section for manifolds if required. For detail dimensions contact factory.
Item # 75022-44-21
Push to latch, turn to unlatch. Can be used as an emergency stop button.
Operating pressure range std. type- 0-145 PSI, air piloted types minimum 35 PSI. Actuation force: std – 7.9 lbs , air pilot. assisted types 1 8 lbs.
Above panel dim are 1.125″ dia x 1.25″H. Behind panel dimensions are 4″ (3 way), 4.5″ (4 way) D. x 1.375″ H x 0.75 W.
For valve specifications see appendix. For detail dimensions contact factory.
Item # 76044-12-00
Three position valves can be used to position cylinder piston rods or switch air supplies to alternate devices. In line spool valves are available in 2 versions; with all ports open or all ports closed in the center (off) position. Springs return the valve to the center position when the coil power is switched off. Valves can be individually mounted using through body holes or assembled on manifolds.
Operating pressure range is 35 to 145 PSI. (Use valves with external pilot for switching lower pressures).
Through body mounting holes are 3/16″.
For valve specifications see appendix. See accessory section for connectors and manifolds. For detail dimensions contact factory.
There are no reviews yet.