Actuation is caused by deflection of spring supported 4 1/2 -inch wire. Can be used to detect passing items on conveyor belts. Allows valve to be mounted close to detected unit and provides a wiping action.
Valve operating pressure range is 35-145 PSI. Minimum pressure 35 PSI. Actuation force at 90 PSI, is approx. 6 ounces.
Body dimensions for 1/8 ported valves are 2.75″ L (3 way), 3.5″ L (4 way) x 1.375″ H x .75″ W. Approximate valve body dimensions for 1/4 ported
valves are 4.75″ L x 2″ H x 1″ W.
Through body mounting holes 3/16″.
For valve specifications see appendix. For detail dimensions contact factory.
Pneumatically operated poppet valves are available in single, double or with priority port actuators. The priority port design overrides the signal from the opposite pilot operator to insure return to home position. Poppet valves rely on O rings and gaskets to seal passage ways within the valve and generally offer higher flow rates than other types of valves.
These valves are available in port sizes of 1/8, 1/4 and 1/2. Pilot ports are 1/8 for all size valves and require minimum of 35 PSI operating pressure. Single air pilot valves have an air supported spring return and require a pilot pressure equal to or greater than the air supply pressure at port 1. Valves can be mounted using through body holes or assembled on manifolds.
Pilot port size (for actuation): 1/8 for all size valves.
Operating pressure range 35 to 145 PSI. Actuation force (pilot pressure): 35 PSI minimum.
Mounting via 4 through body holes 3/16? Dia. (1/2? ported valves- 1/4? Dia.).
For valve specifications see appendix. See accessory section for manifolds if required. For detail dimensions contact factory.
Solenoid operated, air piloted poppet valves are available in single, double, priority and external air pilot supply versions. Priority version overrides signal from opposite solenoid to assure return to valve home position. Valves with external air pilot connections are used when switching pressures below 35 PSI. Poppet valves usually provide higher flow rates than other types of valves because of flow path design. Valves include a red manual override for easy testing. Encapsulated coils provide splash proof protection when used with plug connectors. Valves can be mounted individually using through body holes or assembled on manifolds.
Operating pressure range is 35 to 145 PSI. (Use valves with external pilot for switching lower pressures).
Through body mounting holes are 3/16″ for 1/8 and 1/4 ported valves, 1/4″ for 1/2 ported valves.
For valve specifications see appendix. See accessory section for electrical connectors. For detail dimensions contact factory.
Solenoid operated, air piloted poppet valves are available in single, double, priority and external air pilot supply versions. Priority version overrides signal from opposite solenoid to assure return to valve home position. Valves with external air pilot connections are used when switching pressures below 35 PSI.
Poppet valves usually provide higher flow rates than other types of valves because of flow path design.
Valves include a red manual override for easy testing. Encapsulated coils provide splash proof protection when used with plug connectors. Valves can be mounted individually using through body holes or assembled on manifolds.
Operating pressure range is 35 to 145 PSI. (Use valves with external pilot for switching lower pressures).
Through body holes are 3/16″ for 1/8 and 1/4 ported valves, 1/4 ? for 1/2 ported valves.
For valve specifications see appendix. See accessory section for connectors and manifolds. For detail dimensions contact factory.
Lever valves can be used to manually switch air supplies on equipment or operate cylinders and other devices. Valves can be panel mounted or fastened to a surface via body mounting holes. Handles have a contemporary black molded grip and require 3.4 lbs. of force to operate. Valves are available in spring return, pneumatic return and maintained position versions.
Operating pressure range is 0-145 PSI. Actuation force at 90 PSI, is approx. 3.4 Lbs.
For normally open function on 3 way valves, reverse connect ports 1-3. For 2 way operation, plug port 3.
Panel mounting hole size for 1/8-ported valves is 5/8 inch diameter, for 1/4 ported valves, 7/8 inch. Through body mounting holes are 3/16″ dia.
Typical dimensions of 4 way 1/8 ported valves are 3.75″ L x 1.375″ W x 0.75″ D. For 1/4 ported valves: 4.75″ L x 2″ W x 1″ D. For 3 way valves subtract 0.75″ from L dimension. For pneumatic return valves add 1″ to L dimension. Allow space for fittings and tubing.
For valve specifications see appendix. For detail dimensions contact factory.
Solenoid operated, air piloted poppet valves are available in single, double, priority and external air pilot supply versions. Priority version overrides signal from opposite solenoid to assure return to valve home position. Valves with external air pilot connections are used when switching pressures below 35 PSI.
Poppet valves usually provide higher flow rates than other types of valves because of flow path design.
Valves include a red manual override for easy testing. Encapsulated coils provide splash proof protection when used with plug connectors. Valves can be mounted individually using through body holes or assembled on manifolds.
Operating pressure range is 35 to 145 PSI. (Use valves with external pilot for switching lower pressures).
Through body holes are 3/16″ for 1/8 and 1/4 ported valves, 1/4 ? for 1/2 ported valves.
For valve specifications see appendix. See accessory section for connectors and manifolds. For detail dimensions contact factory.
Three way poppet design valves are solenoid operated, air pilot assisted. Valves include a red manual override lever for easy testing of pneumatic circuits. Coils are encapsulated for long life. Available in standard versions, or with a port for external air supply used for switching pressures below 35 PSI.
Operating pressure range is 35 to 145 PSI. (Use valves with external pilot for switching lower pressures).
For 2-way operation plug exhaust port 3. Through body mounting holes are 3/16″ for 1/8 and 1/4 ported valves, 1/4″ for 1/2 ported valves.
For valve specifications see appendix. See accessory section for electrical connectors. For detail dimensions contact factory.
Three way poppet design valves are solenoid operated, air pilot assisted. Valves include a red manual override lever for easy testing of pneumatic circuits. Coils are encapsulated for long life. Available in standard versions, or with a port for external air supply used for switching pressures below 35 PSI.
Operating pressure range is 35 to 145 PSI. (Use valves with external pilot for switching lower pressures).
For 2-way operation plug exhaust port 3. Through body mounting holes are 3/16″ for 1/8 and 1/4 ported valves, 1/4″ for 1/2 ported valves.
For valve specifications see appendix. See accessory section for electrical connectors. For detail dimensions contact factory.
Used as a pneumatic limit switch or position detector. Roller arm travel is 3/8? (10mm). Actuating force is 4.5 Lbs. Options include valves with pneumatic reset used in conjunction with other controlling devices to reset valve. A double roller lever valve can be used on machine carriages to reverse direction of travel.
Operating pressure range is 0-145 PSI. Actuation force @ 90 PSI, is approx. 4.5 Lbs.
For normally open function on 3 way valve, reverse connect ports 1-3. For 2 way operation, plug port 3.
Typical valve body dimensions are 2.5? L (3 way), 3.15? L (4 way) x 1.375? H x .75? W. Add 1? to L dim. for pneumatic reset types. Through body mounting holes are 3/16? diameter.
Roller Lever extends 1.343? beyond body and travel is .39? +/- .04?.
For valve specifications see appendix. For detail dimensions contact factory.
Solenoid operated, air piloted poppet valves are available in single, double, priority and external air pilot supply versions. Priority version overrides signal from opposite solenoid to assure return to valve home position. Valves with external air pilot connections are used when switching pressures below 35 PSI.
Poppet valves usually provide higher flow rates than other types of valves because of flow path design.
Valves include a red manual override for easy testing. Encapsulated coils provide splash proof protection when used with plug connectors. Valves can be mounted individually using through body holes or assembled on manifolds.
Operating pressure range is 35 to 145 PSI. (Use valves with external pilot for switching lower pressures).
Through body holes are 3/16″ for 1/8 and 1/4 ported valves, 1/4 ? for 1/2 ported valves.
For valve specifications see appendix. See accessory section for connectors and manifolds. For detail dimensions contact factory.
Solenoid operated, air piloted poppet valves are available in single, double, priority and external air pilot supply versions. Priority version overrides signal from opposite solenoid to assure return to valve home position. Valves with external air pilot connections are used when switching pressures below 35 PSI. Poppet valves usually provide higher flow rates than other types of valves because of flow path design. Valves include a red manual override for easy testing. Encapsulated coils provide splash proof protection when used with plug connectors. Valves can be mounted individually using through body holes or assembled on manifolds.
Operating pressure range is 35 to 145 PSI. (Use valves with external pilot for switching lower pressures).
Through body mounting holes are 3/16″ for 1/8 and 1/4 ported valves, 1/4″ for 1/2 ported valves.
For valve specifications see appendix. See accessory section for electrical connectors. For detail dimensions contact factory.
Operating pressure range is 35 to 145 PSI. Minimum operating pressure is 35 PSI. Actuation force at 90 PSI. is approx 14 ozs.
Panel mounting hole is 7/8 inch (22 mm) diameter. Above panel dimensions are 1.375″ Dia. x 1″ H. (Mushroom) or 0.625″ H. (Shroud Head).
Behind panel dimensions of 3 way valve – 3.75″ D x 1.375″ H x 0.75″ W; 4 way valve – 4.25″ D x 1.375″ H x 0.75″ W.
Allow space for fittings and tubing.
Valve through body mounting holes are 3/16″ diameter.
For valve specifications see appendix. For detail dimensions contact factory.
Flush Head pushbuttons are used to prevent accidental operation or provide flat panel appearance. Button is flush with shroud surface and diameter is 1-3/8 inch.
Operating pressure range is 0 to 145 PSI. Actuation force at 90 PSI. is approx. 7.9 Lbs.
For normally open function on 3 way valve reverse connect ports 1-3. For 2 way operation, plug port 3.
Panel mounting hole is 1 3/16 inch (30 mm) diameter. Above panel dimensions are 1.375″ Dia. x 0.875″ H. (Mushroom) or 0.375″ H. (Flush Head).
Behind panel dimensions of 3 way valve – 3.25″ D x 1.375″ H x 0.75″ W; 4 way valve- 4″ D x 1.375″ H x 75″ W. Allow space for fittings and tubing.
Valve through body mounting holes are 3/16″ diameter.
For valve specifications see appendix. For detail dimensions contact factory.
One way roller operates valve only in one direction. Used as a pneumatic limit switch or position detector. Roller arm travel is 3/8? (10mm). Actuation force is 4.5 Lbs.
Operating pressure range 0-145 PSI. Actuation force at 90 PSI, is approx. 4.5 Lbs.
Valve body dimensions are 1.812″ L x .625″ W x 1.25″ H. Roller arm extends 1.89″ beyond body and travel is .375″ in actuate direction and .3125 in non-actuate direction. Through body mounting holes 3/16″ diameter.
For valve specifications see appendix. For detail dimensions contact factory.
Flush Head pushbuttons are used to prevent accidental operation or provide flat panel appearance. Button is flush with shroud surface and diameter is 1-3/8 inch.
Operating pressure range is 0 to 145 PSI. Actuation force at 90 PSI. is approx. 7.9 Lbs.
For normally open function on 3 way valve reverse connect ports 1-3. For 2 way operation, plug port 3.
Panel mounting hole is 1 3/16 inch (30 mm) diameter. Above panel dimensions are 1.375″ Dia. x 0.875″ H. (Mushroom) or 0.375″ H. (Flush Head).
Behind panel dimensions of 3 way valve – 3.25″ D x 1.375″ H x 0.75″ W; 4 way valve- 4″ D x 1.375″ H x 75″ W. Allow space for fittings and tubing.
Valve through body mounting holes are 3/16″ diameter.
For valve specifications see appendix. For detail dimensions contact factory.